Technical data, This cooker is designed for use on either, Dimensions – Rangemaster Classic 110 User Manual
Page 31: Connections, Ratings

31
Technical Data
This cooker is designed for use on either :-
NATURAL GAS (Cat I2H ) at 20mbar or
LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS
AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height including optional splashback
minimum
1063mm
maximum 1190mm
Height to hotplate
minimum
893mm
maximum 920mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas
Electric
Rp
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Injector
Injector
Hotplate
Wok burner
3.5kW
internal 80
3.5kW(246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Ovens
3.2kW
237
2.9kW (224g/h)
85
Grill
2.73kW 190
2.73kW (192g/h) 85
Gas burner inputs based on Gross Calorific Value
Warmer
160W
160W