beautypg.com

Raypak RFSDV34RFPAU User Manual

Page 19

background image

If an error code 8 is observed while performing the testing, complete the
following:

1. Confirm that the gas valve is not in the REMOTE mode.

• If the valve is producing error code 8 while in the REMOTE

mode, the valve is defective and should be replaced.

• If the valve is producing error code 8 while in the LOCAL mode,

go to the next step.


2.
Slide the REMOTE/LOCAL switch to REMOTE and program the
remote control as per item 6 page 13. The error code will clear itself after
approximately 1.5 minutes and return to normal operation.


Page 19 of 27

This manual is related to the following products: