Ricoh R5RL User Manual
Page 9
6
• R
×
5RL50A
Topt=25˚C
• R
×
5RL40A
Topt=25˚C
Symbol
Item
V
OUT
Output Voltage
I
OUT
Output Current
∆
V
OUT
Load Regulation
∆
I
OUT
V
DIF
Dropout Voltage
I
SS
Quiescent Current
∆
V
OUT
∆
V
IN
Line Regulation
V
IN
Input Voltage
∆
V
OUT
Output Voltage
∆
Topt
Temperature Coefficient
Conditions
MIN.
TYP.
MAX.
Unit
V
IN
=6.0V
3.900
4.000
4.100
V
10µA
≤
I
OUT
≤
10mA
V
IN
=6.0V
45
65
mA
V
IN
=6.0V
1mA
≤
I
OUT
≤
65mA
50
75
mV
I
OUT
=1mA
25
38
mV
V
IN
=6.0V
1.2
3.6
µA
I
OUT
=1mA
V
OUT
+0.5V
≤
V
IN
≤
10V
0.05
0.2
%/V
10
V
I
OUT
=10mA
±100
ppm/˚C
–30˚C
≤
Topt
≤
80˚C
Symbol
Item
V
OUT
Output Voltage
I
OUT
Output Current
∆
V
OUT
Load Regulation
∆
I
OUT
V
DIF
Dropout Voltage
I
SS
Quiescent Current
∆
V
OUT
∆
V
IN
Line Regulation
V
IN
Input Voltage
∆
V
OUT
Output Voltage
∆
Topt
Temperature Coefficient
Conditions
MIN.
TYP.
MAX.
Unit
V
IN
=7.0V
4.875
5.000
5.125
V
10µA
≤
I
OUT
≤
10mA
V
IN
=7.0V
55
80
mA
V
IN
=7.0V
1mA
≤
I
OUT
≤
80mA
60
90
mV
I
OUT
=1mA
25
38
mV
V
IN
=7.0V
1.3
3.9
µA
I
OUT
=1mA
V
OUT
+0.5V
≤
V
IN
≤
10V
0.05
0.2
%/V
10
V
I
OUT
=10mA
±100
ppm/˚C
–30˚C
≤
Topt
≤
80˚C