beautypg.com

Dry air, Heat pumps, Desert climates not a problem – Raypak RHP-115LHHC User Manual

Page 2: Features and benefits, Dimensions and technical specifications

background image

RHP-115LHHC

State-of-the-art control panel,

with Direct Set temperature

control and LED

temperature readout. LED

lights monitor the heat

pumps’ operational status

at all times.

34-1/2

37

2"
WATER
CONNECTION

34-1/2

8

10-7/16

4-11/16

2151 Eastman Avenue, Oxnard CA 93030 • (805) 278-5300 Fax (800) 872-9725

www.raypak.com

• Exclusive DuraSteel

TM

Cabinet

Polyester coated, non-corrosive cabinet is more durable than
plastic heat pump cabinets.

• Oversized Coated Air Coils

Oversized fins maximize heating in low humidity conditions.
Unique fin coating prevents corrosion, even in salt air.

• Venturi Fan Cowling

High capacity fan provides unrestricted air flow for better
heating.

• 10 Year Limited Warranty

Customer direct toll free number 800-260-2758

• Solid State Controls

Accurately monitors your pool’s water temperature settings.

• Internal Valving

Automatically compensates for normal day-to-day changes in
your pool’s hydraulics, maximizing heat transfer efficiency.

• Back-Flow Check Valves

Reduce the possibility of damage from chlorinating devices.

• Exclusive Refrigerant Receiver Tank

Allows larger refrigerant charge and provides more efficient
heating at lower air temperatures without additional
compressor stress.

• System Compatibility

Compatible with the latest automated pool control systems.

Features and Benefits

Catalog Number: 6000.26A Effective 08-06-02 Replaces 04-01-02

Raypak reserves the right to change these specifications without notice.

All dimensions

are in inches.

RHP-115LH
RHP-115LHHC

Heat Pumps

Dimensions and Technical Specifications

MODEL

115LH

115LHHC

Heat BTU Output

112,000

112,000

80°F Air 80% RH 80°F Water

Cool BTU Output

N/A

83,000

C.O.P.

6.4

6.4

Compressor

Scroll

Scroll

Voltage

208/230V-1Ph-60Hz

Minimum Circuit Ampacity

40

40

Maximum Breaker Size (Amps)

50

50

Electrical Input (kw)

5.12

5.12

Water Flow (gpm)

15-80

15-80

Shipping Weight (lbs.)

375

385

ETL tested and rated in accordance with ASHRAE standard 146-198 and PHPMA
addendum test procedure.

A standard heat

pump coil can not

gather enough

moisture to generate

adequate heat in a

dry climate.

The coil in a Raypak

LH heat pump is

oversized, which

allows it to gather

more moisture from

the air. More moisture

equals more heat.

Standard Coil Size

Raypak LH Oversized Coil

Dry Air?

Desert climates not a problem!

You can

heat

and

cool

with

the RHP-115LHHC

LHHC Series control

panel shown

This manual is related to the following products: