ROWENTA Werke User Manual
Page 9

TROUBLESHOOTING
Problems
Possible causes
Solutions
The steam
The appliance is not
Check that your
generator
switched on.
appliance is correctly
ON light does
plugged in and press
not light up.
the on/off switch
(located on the front
of the appliance).
Water runs
You are using steam
Decrease the steam
through the
before the iron is hot
output while ironing
holes in the
enough.
(steam control dial on
soleplate.
the control panel).
Wait for the iron tempe-
rature indicator light to
go out before ironing.
The water has condensed
Press the steam button
in the tubes because you
away from your ironing
are using steam for the
board until the iron
first time or you have not
produces steam.
used it for some time.
White streaks
Your boiler has a build-up Rinse out the boiler after
come through
of scale because it is not
every 10 uses (See section
the holes in the rinsed out regularly.
Rinsing Out the Boiler).
soleplate.
If your water is hard,
increase the frequency.
Brown streaks
You are using chemicals
Never add this type of
come through
descaling agents or
product (see our recom-
the holes in the additives in the water for
mendations regarding
soleplate and
ironing.
water to be used).
stain the linen.
Your linen is not rinsed
Ensure linen is rinsed
sufficiently or you have
thoroughly to remove
ironed a new garment
any soap deposits or
before washing it.
chemicals on new
garments.
Build-up
You are ironing at too
See our recommenda-
on soleplate.
high a temperature.
tions regarding tempera-
ture control setting.
You are using starch.
Always spray starch onto
the reverse side of the
fabric to be ironed.
There is little or The boiler does not oper-
Check that the removable
no steam.
ate, or the red light on the water tank is securely in
control panel comes on
place and press the boiler
even though there is still
reset button located on
water left.
the control panel.
The removable
Fill the removable water
water tank is
tank and press the boiler
empty (red
reset button located on
“water tank
the control panel.
empty“ light on).
The steam control dial
Increase the steam output
is set at minimum.
(control dial on control
panel).
Steam escapes
The drain screw has not
Tighten the drain screw
from the drain- been tightened correctly.
correctly.
age screw.
Steam escapes
Possibility of leak.
Stop using the generator
under the
and contact an Approved
appliance.
Service Center.
If troubleshooting does not assist, before consulting
the retailer regarding their return/exchange policy,
please telephone consumer service at 781-396-0600.