TROUBLESHOOTING

Problems

Possible causes

Solutions

The steam

The appliance is not

Check that your

generator

switched on.

appliance is correctly

ON light does

plugged in and press

not light up.

the on/off switch
(located on the front
of the appliance).

Water runs

You are using steam

Decrease the steam

through the

before the iron is hot

output while ironing

holes in the

enough.

(steam control dial on

soleplate.

the control panel).
Wait for the iron tempe-
rature indicator light to
go out before ironing.

The water has condensed

Press the steam button

in the tubes because you

away from your ironing

are using steam for the

board until the iron

first time or you have not

produces steam.

used it for some time.

White streaks

Your boiler has a build-up Rinse out the boiler after

come through

of scale because it is not

every 10 uses (See section

the holes in the rinsed out regularly.

Rinsing Out the Boiler).

soleplate.

If your water is hard,
increase the frequency.

Brown streaks

You are using chemicals

Never add this type of

come through

descaling agents or

product (see our recom-

the holes in the additives in the water for

mendations regarding

soleplate and

ironing.

water to be used).

stain the linen.

Your linen is not rinsed

Ensure linen is rinsed

sufficiently or you have

thoroughly to remove

ironed a new garment

any soap deposits or

before washing it.

chemicals on new
garments.

Build-up

You are ironing at too

See our recommenda-

on soleplate.

high a temperature.

tions regarding tempera-
ture control setting.

You are using starch.

Always spray starch onto
the reverse side of the
fabric to be ironed.

There is little or The boiler does not oper-

Check that the removable

no steam.

ate, or the red light on the water tank is securely in
control panel comes on

place and press the boiler

even though there is still

reset button located on

water left.

the control panel.

The removable

Fill the removable water

water tank is

tank and press the boiler

empty (red

reset button located on

“water tank

the control panel.

empty“ light on).
The steam control dial

Increase the steam output

is set at minimum.

(control dial on control
panel).

Steam escapes

The drain screw has not

Tighten the drain screw

from the drain- been tightened correctly.

correctly.

age screw.
Steam escapes

Possibility of leak.

Stop using the generator

under the

and contact an Approved

appliance.

Service Center.

If troubleshooting does not assist, before consulting
the retailer regarding their return/exchange policy,
please telephone consumer service at 781-396-0600.