beautypg.com

Roper ELECTRIC DRYER REX4625E User Manual

Electric dryer, Closet confined area, Recessed area

background image

Electric Dryer

PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

RES7646J
RES7646K
RES7648E
RES7648J
RES7648K
REX3614J
REX3614K
REX3615E

REX4625E
REX4634J
REX4634K
REX4635E
REX5634J
REX5634K
REX5635E

Electrical:

A four-wire or three-wire, single phase,

120/240-volt, 60-Hz, AC-only, electrical supply is
required on a separate 30-ampere circuit, fused on
both sides of the line. Use 10 gauge solid copper
wire. A time-delay fuse or circuit breaker is
recommended.

Exhaust venting:

Exhaust your dryer to the

outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do Not
use plastic or metal foil vent. Exhaust outlet hood
must be at least 12 inches from the ground or any
object that may be in the path of the exhaust.

Closet confined area

4"

4"

Preferred

Number of

Rigid

Flexible

90° elbows (fully

extended)

When you have a 4" hood

Maximum length of 4"

diameter metal vent

0

1

2

3

4

64 ft.

54 ft.

44 ft.

35 ft.

27 ft.

36 ft.

31 ft.

27 ft.

25 ft.

23 ft.

Acceptable

Number of

Rigid

Flexible

90° elbows (fully

extended)

When you have a 2-1/2" hood

Maximum length of 4"

diameter metal vent

0

1

2

3

4

58 ft.

48 ft.

38 ft.

29 ft.

21 ft.

28 ft.

23 ft.

19 ft.

17 ft.

15 ft.

2-1/2"

Select the route that will provide the straightest and most direct path
outdoors. Plan the installation to use the fewest number of elbows and
turns. Avoid making 90° turns.

When using elbows or making turns, allow as much room as possible.
Bend flexible metal vent gradually to avoid kinking.

Determine vent length

1. See the exhaust vent length chart that matches your type hood for the

maximum vent lengths you can use.

Do not use vent runs longer than specified in exhaust vent length charts.

2. Determine the number of elbows you will need.

3. In the column listing the type of metal vent you are using (rigid or

flexible), find the maximum length of metal vent on the same line as the
number of elbows.

The maximum length using a 2" x 6" rectangular vent with 2 elbows and
a 2-1/2" exhaust hood is 8 ft.

3"

3"

48 sq. in.

**

24 sq. in.

**

14"

max.

front view

1"

closet

door

** Minimum top and bottom air openings for closet door.

*** External exhaust elbow requires additional space.

0" *

0" *

front view

18"

If a closet door is installed: The minimum unobstructed air
openings are required. Louvered doors with equivalent air
openings are acceptable.

*Wall, door and floor molding may require

additional spacing.

side view

Recessed
Closet

Back

5"/0"
5"/4"

Sides
1"/0"
1"/0"

Top

18"/18"
18"/18"

Front

1"/1"

Recommended/Minimum

Recessed

area

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. 3397618

01-09-03

4"

***

*from floor with dryer

feet extended 1 inch

29"

28" max.

14-1/2"

dryer exhaust
vent

power supply
cord/cable
opening

6"*

42-3/8"*

terminal
block cover

DOOR CLEARANCE DIMENSIONS

Large side-swing

door (reversible)

17-3/4"

22-3/4"

22-3/4"

7"

Extra-large hamper door

Small side-swing door

15-1/4"

15-1/4"

15-1/4"

13-3/4"

13-3/4"

25-5/8"

8-1/4"

8-3/4"

22-3/4"

22-3/4"

19-1/8"

Super-large

side-swing door (reversible)

3-7/8"

®