8
3.4.1 A-6011 Mini Din Female and PS-2 male connector:
Cable Length: To GPS-6017: 1 meter
RS-232 to PS-2: 45 cm
Note: PS-2 with long cable (1 meter) is for GPS
PS-2 with short cable (45mm) is for power
3.4.1.1 Mini Din Female connector function definition:
Pin Signal
Name
1 N.C
2 Tx
3 Rx
4 N.C
5 Ground
6 N.C
7 N.C
8 N.C
9 DGPS
in
N.C = No connection
3.4.1.2 PS-2 male connector function definition (to PC):
Pin Signal
Name
1
+3 ~ +6V
2 N.C
3 N.C
4 Ground
5 N.C
6 N.C
N.C = No connection
Remarks: A-6011-S is for COM+PS-2 converting to PS-2 female. If you have an old GPS receiver with
standard COM + PS-2 male connector, you may choose an A-6011-S. Then you can use your old
GPS receiver with PDA or USB version PC. PDAs with TTL output are not excluded.
3.4.2 A-6011-E Mini Din Female w/Pin-9 power:
Cable Length: 0.5 meter
3.4.2.1 Mini Din Female connector function definition:
Pin Signal
Name
1 N.C
2 Tx
3 Rx
4 N.C
5 Ground
6 N.C
7 N.C
8 N.C
9 +(3~6)VDC
N.C = No connection