beautypg.com

Reebok Fitness RBTL22920 User Manual

Page 26

background image

26

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and

UNPLUG THE POWER CORD. If the walking belt has
shifted to the left,
use the allen wrench to turn the left
rear roller bolt clockwise 1/2 of a turn; if the walking belt
has shifted to the right,
turn the bolt counterclockwise
1/2 of a turn. Be careful not to overtighten the walking
belt. Plug in the power cord, insert the key and run the
treadmill for a few minutes. Repeat until the walking belt is
centered.

b. If the walking belt slips when walked on, first remove the

key and UNPLUG THE POWER CORD. Using the allen
wrench, turn both rear roller bolts clockwise 1/4 of a turn.
When the walking belt is correctly tightened, you should
be able to lift each side of the walking belt 3 to 4 inches off
the walking platform. Be careful to keep the walking belt
centered. Plug in the power cord, insert the key, and walk
on the treadmill for a few minutes. Repeat until the walk-
ing belt is properly tightened.

PROBLEM: The displays of the console do not function properly

SOLUTION: a. Remove the key from the console and UNPLUG THE

POWER CORD. Next, remove the screws from the hood
and carefully remove the hood. Locate the Reed Switch
(17) and the Magnet (12) on the left side of the Pulley (11).
Turn the Pulley until the Magnet is aligned with the Reed
Switch. Make sure that the gap between the Magnet and
the Reed Switch is about 1/8”.
If necessary, loosen the
indicated Screw (44) and move the Reed Switch slightly.
Retighten the Screw. Re-attach the hood and run the tread-
mill for a few minutes to check for a correct speed reading.

PROBLEM: The heart rate monitor does not function properly

SOLUTION: a. If the chest pulse sensor does not function properly, refer to CHEST

PULSE SENSOR TROUBLESHOOTING on page 8.

b. If the chest pulse sensor still does not function properly, the battery

should be changed. To replace the battery, locate the battery cover
on the back of the sensor unit. Insert a coin into the slot in the cover
and turn the cover counterclockwise to the “open” position. Remove
the cover.

Next, remove the old battery from the sensor unit. Insert a new CR
2032 battery
, making sure that the writing is on top. In addition,
make sure that the rubber gasket is in place in the sensor unit.
Replace the battery cover and turn it to the closed position.

CR2032
Battery

Rubber
Gasket

b

12

17

44

Top

View

1/8”

11

a

a

b