Installation, Wiring, Optional remote control – Regency ULTIMATE U38-LP User Manual
Page 13: Final check, Caution
Regency U38 ULTIMATE Freestanding Gas Heater
13
WIRING
This heater does not require a 120V A.C.
supply for operation. In case of a power
failure, the burner switch and the optional
remote control/thermostat will continue to op-
erate. However, a 120V A.C. power supply is
needed for the fan/blower operation.
Caution: Ensure that the wires do not touch any hot surfaces and are away from
sharp edges.
OPTIONAL REMOTE
CONTROL
Use the Regency Remote Control Kit approved
for this unit. Use of other systems may void
your warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
Thermostat Wire Table
INSTALLATION
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1) Clocking the appliance to ensure the cor-
rect firing rate (rate noted on label) at 15
minutes.
2) If required, adjusting the primary air to
ensure that the flame does not carbon. First
allow the unit to burn for 15 min. to stabilize.
3) Check for proper draft.
CAUTION
Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of
the manufacturer.
1) Choose a convenient location on the wall to
install the receiver and the receptacle box
(protection from extreme heat is very impor-
tant). Run wires from the fireplace to that
location, use Thermostat Wire Table.
2) Connect the wires as per the wiring dia-
gram above.
CAUTION
Do not connect the millivolt
remote control wires to
the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size Max. Length
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly grounded three-
prong receptacle. Do not cut or remove the grounding prong from this plug.
CAUTION:
Label all wires
prior to discon-
nection when
servicing con-
trols. Wiring er-
rors can cause
improper and
dangerous op-
eration.