beautypg.com

Troubleshooting guide, Storage 11. disposal – RedMax STICK HEZ2450S User Manual

Page 17

background image

US-17

HEZ2450S/HEZ3050S

U
S

Case 1. Starting failure

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel

drain it and with correct fuel

fuel filter

fuel filter is clogged

clean

carburetor adjustment screw

out of normal range

adjust to normal range

sparking (no spark)

spark plug is fouled/wet

clean/dry

plug gap is incorrect

correct (GAP: 0.6 – 0.7 mm)

spark plug

disconnected

retighten

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

PROBABLE CAUSES

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

replace

cylinder fin, fan cover

clogged with dust

clean

When your unit seems to need further service, please consult with our service shop in your area.

12. Troubleshooting guide

• Aged fuel is one of major causes of

engine starting failure. Before storing
the unit, empty the fuel tank and run
the engine until it uses all the fuel left in
the fuel line and the carburetor. Store
the unit indoor taking necessary
measures for rust prevention.

10. Storage

11. Disposal

• When disposing your machine, fuel or

oil for the machine, be sure to allow
your local regulations.

This manual is related to the following products: