beautypg.com

Installation (continued), Connecting the power transformers, Mounting the transformer cover – NuTone IM-440 Series User Manual

Page 7

background image

7

CONNECTING THE
POWER TRANSFORMERS

1. Refer to Figure 14. The transformers’ primary leads

should already be connected to the 120 volt AC house
supply wiring. Be sure power is off before connecting
transformers to master unit.

2. Locate the two (2) sets of red/wht transformer leads on

the lower left corner of the master unit. Connect one pair
of low voltage leads to each transformer located in the
bottom of the rough-in.

INSTALLATION (Continued)

IMPORTANT WARNING!

THE POWER TRANSFORMER CONTAINS AN
INTERNAL FUSE.

DO NOT SHORT THE LOW VOLTAGE CONNECTING
SCREWS OF THE TRANSFORMER OR THE
TRANSFORMER WILL BE DESTROYED!

CAUTION

BE SURE THE AC POWER IS OFF BEFORE
CONNECTING THE POWER TRANSFORMERS. DO
NOT TURN AC POWER ON TO TRANSFORMERS
UNTIL ALL WIRING AT THE REMOTE AND MASTER
STATIONS IS COMPLETE!

FIGURE 14

FIGURE 15

MOUNTING THE TRANSFORMER COVER

IMPORTANT: The transformer cover must be installed
for proper operation of the intercom.

1. Refer to Figure 15. Remove the left front and right rear

screws from the transformer enclosure. Set screws aside
for later installation.

2. Position the transformer cover (with insulator positioned

towards transformers) over the transformer enclosure so
holes in cover align with holes in enclosure.

3. Fasten cover with two (2) screws previously removed.