beautypg.com

Installation – Napoleon Fireplaces SAVOY OS11 User Manual

Page 4

background image

General information

Nominal heat

output

Oil consumption **

Chimney draft required

Weight

Flue outlet inside

diameter

max speed

min speed

max speed

min speed

27,300 BTU/hr

.25 US gal/hr

.073 US gal/hr

.06" w.c.

.024" w.c.

220 lbs

5 inches

8 kW

0.96 liter/h

0,28 liter/h

15 Pa

6 Pa

100 kg

125 mm

** 1 pint = 0.568 liter

1 quart = 1.136 liter

1 gallon (Brit.) = 4.546 liter

1 US gal = 3.785 liter

1 liter = 1.760 pints

1 liter = 0.879 quart

1 liter = 0.22 gal (Brit.)

1 liter = 0.26 gal (US)

Pints, quarts and gallons are Canadian unless otherwise noted.

Care of enamelled parts

Do not use abrasive cleaners to clean these parts. Buff lightly with a clean, dry cloth. Porcelain enamel components must
be handled with care. The baked-on finish is “glasslike”. If struck, it will chip. Touch-up paint is available through your
Napoleon dealer.

Care of glass

If the glass is not kept clean permanent discolouration and / or blemishes may result. Normally a hot burn will clean the
glass. The most common reason for dirty glass is running the unit at a low burning rate. If it is necessary to clean the glass,
use a soft cloth with a nonabrasive cleaner. Coarse cleaning materials may cause scratches or otherwise damage the
glass. Scratches can develop into cracks or breaking of the glass.

DO NOT CLEAN GLASS WHEN HOT !

The glass is very strong for maximum performance. However, always close the door gently. If the glass should ever crack
while the fire is burning, do not open the door until the fire is out and do not operate the stove again until the glass has
been replaced with new borosilicate glass, available from your Napoleon / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE
MATERIALS.
Check gaskets and seals regularly.

INSTALLATION

WARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency
or the oil supplier.

H

Unit and specifications

593

(2

3

3/

8"

)

288

(1

1

3/

8"

)

5 5 2 , 5 ( 2 1 3 / 4 " )

5 0 5 ( 2 0 " )

1 4 5

( 5 3 / 4 " )

5 3 5 ( 2 1 " )

708

(2

8"

)

Ø 1 2 5 ( 5 " ) i n t .

Ø 1 2 5 ( 5 " ) i n t .

Ø 1 0 0

( 4 " ) e x t .

Figure 1

Document n° 1043-1 ~ 15/01/2002