beautypg.com

Installer final checklist – Nexgrill 720-0230 User Manual

Page 19

background image

17

BEFORE TESTING
Make sure that all packing material is removed from the
grill including the burner tie-down straps.

DO NOT SMOKE WHILE LEAK TESTING.

NEVER PERFORM LEAK TEST WITH AN OPEN
FLAME.

Make a soap solution of one part liquid detergent and
one part water. You will need a spray bottle, brush, or
rag to apply the solution to the fittings. For the initial
leak test, make sure the L.P. cylinder is full.

TO TEST
Make sure all control valves are in the “OFF” position.
Turn the gas supply on. Check all connections from the
L.P. cylinder up to and including the connection to the
manifold pipe assembly (the pipe that goes to the
burners). Soap bubbles will appear where a leak is
present. If a leak is present, immediately turn off the gas
supply, tighten any leaking fittings, turn gas on, and
recheck. Should the gas continue to leak from any or all
of the fittings, turn off the gas supply, and contact our
customer service at 1-800-913-8999.

Only those parts recommended by the manufacturer
should be used on the grill. Substitution will void the
warranty. Do not use the grill until all connections have
been checked and do not leak.

Gas flow check:

Each grill burner is tested and adjusted at the factory
prior to shipment; however, variations in the local gas
supply may make it necessary to adjust the burners. The
flames of the burners should be visually checked.

Flames should be blue and stable with no yellow tips,
excessive noise or lifting. If any of these conditions exist,
check to see if the air shutter or burner ports are blocked
by dirt, debris, spider webs, etc. If you have any
questions regarding flame stability, please call customer
service 1-800-913-8999.

ALWAYS CHECK FOR LEAKS AFTER
EVERY L.P. TANK CHANGE

Check all gas supply fittings for leaks before each use.
It is handy to keep a spray bottle of soapy water near
the shut-off valve of the gas supply line. Spray all the
fittings. Bubbles indicate leaks.

Disconnected L.P. cylinders must have threaded valve
plugs tightly installed, and must not be stored in a
building, garage or any other enclosed area.

The gas must be turned off at the supply cylinder
when the unit is not in use.

If the appliance is stored indoors the cylinder must be
disconnected and removed from the appliance.
Cylinders must be stored outdoors in a well-
ventilated area out of the reach of children.

.

INSTALLER FINAL CHECKLIST

ˆ Specified clearance maintained 24” from

combustibles.

ˆ All internal packaging removed.
ˆ Knobs turn freely.
ˆ Burners are tight and sitting properly on orifices.
ˆ Pressure regulator connected and set for 11.2” W.C.

L.P. gas. Gas connections to grill using hose &

regulator assembly provided (pre-set for 11.0” water
column).

ˆ Unit tested and free of leaks.
ˆ User informed of gas supply shut off valve location.

USER, PLEASE RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE.

PROPANE CYLINDER CAUTIONS


a) Do not store a spare LP-gas cylinder under or near this appliance.
b) NEVER fill the cylinder beyond 80 percent full.
c) If the information in “a” and “b” is not followed exactly, a fire causing death or serious

injury may occur.