beautypg.com

Northern Industrial Tools 1/2 HP SUMP PUMP User Manual

Page 7

background image

6

1.

THE ELECTROPUMP

DOES NOT

PUMP

W

ATER,

THE MOT

OR DOES NOT

RUN.

2.

THE PUMP

DOES NOT

SUPPL

Y

W

ATER

BUT

THE MOT

OR IS RUNNING.

3.

THE PUMP

SUPPLIES

A

LIMITED

AMOUNT

OF W

ATER.

4.

INTERMITTENT

OPERA

TION

1.

No electricity

.

2.

Plug inserted incorrectly

.

3.

Enabled safety switch.

4.

Blocked safety switch.

5.

Damaged motor or condenser

.

1.

Obstructed suction grid.

2.

Blocked check valve.

3.

Air in impeller body (air Bubbles.)

1.

Partially obstructed suction gird.

2.

Obstructed pipe.

3.

W

om impeller

.

1.

Solid particles prevent the free

rotation of the impeller

.

2.

The temperature of the fluid is

too high.

3.

Vollage out of

f range.

4.

The fluid is too dense.

5.

Faulty motor

.

Verify that voltage is present and

that the plug is correctly inserted.

Reset the safety switch. If the safety

switch is once more enabled, Contact a

speciallzed electrician.

Remove possible obstructions from the

impeller

.

Contact the Customer

Assistance Service.

Clean the grid.

Clean or replace the value.

Perform several start-ups in order to

remove all the air

.

Clean the grid.

Remove the obstructions.

Contact the Customer

Assistance Service.

Renmove the foreign particles.

Supply the pump in accordance with

nameplate data.

Dilute the pumped fluid.

Contact the Customer

Assistance Service.

PROBLEM

POSSIBLE CAUSE

REMEDY