beautypg.com

Chapter 3 transceiver performance testing, 0 general, 0 setup – Nikon RADIUS CM200 User Manual

Page 37

background image

Chapter 3

TRANSCEIVER PERFORMANCE TESTING

1.0

General

These radios meet published specifications through their manufacturing process by utilizing high-
accuracy laboratory-quality test equipment. The recommended field service equipment approaches
the accuracy of the manufacturing equipment with few exceptions. This accuracy must be
maintained in compliance with the manufacturer’s recommended calibration schedule.

2.0

Setup

Supply voltage is provided using a power supply (13.8 Vdc for low power models, 13.6 Vdc for high
power models). The equipment required for alignment procedures is connected as shown in the
Radio Tuning Test Setup Diagram, Chapter 4, Figure 4-6.

Initial equipment control settings should be as indicated in Table 3-1. The remaining tables in this
chapter contain the following related technical data:

Table Number

Title

3-2

Test Environments

3-3

Test Channel Spacing

3-4

Test Frequencies

3-5

Transmitter Performance Checks

3-6

Receiver Performance Checks

Table 3-1 Initial Equipment Control Settings

Service Monitor

Test Set

Power Supply

Monitor Mode: Power Monitor

Spkr set: A

Voltage: 13.8 Vdc (low
power models) 13.6 Vdc
(high power models)

RF Attn: -70

Spkr/load:
Speaker

DC On/Standby:
Standby

AM, CW, FM: FM

PTT: OFF

Volt Range: 20V

Oscilloscope Source: Mod
Oscilloscope Horiz: 10mSec/Div
Oscilloscope Vert: 2.5 kHz/Div
Oscilloscope Trig: Auto
Monitor Image: Hi
Monitor BW: Nar
Monitor Squelch: mid CW
Monitor Vol: 1/4 CW

Current: 20A