6 powering up/down, 1 before powering up, 2 powering up – Network Technologies DVB-ASI to IP User Manual
Page 24: 3 powering down, Powering up/down, Before powering up, Powering up, Powering down

ASI-IP-GTW User's Manual
Page
24
Table 10. ASI port LEDs
Each Ethernet port (data and management) has two LEDs associated
with it.
Table 11. Ethernet port LEDs
2.6 Powering Up/Down
2.6.1 Before Powering up
Before powering-up the unit, please check the following:
o
The unit is installed in a suitable location
o
The unit has been connected to external equipment as required
2.6.2 Powering Up
Power up the unit by inserting the power cable connected to a power
source.
The cooling fans will start up in a full-speed mode. When the unit has
finished the start-up procedure, the fans will run at normal speed.
Please check that the all cooling fans are rotating. If they are not,
switch of the unit immediately.
2.6.3 Powering Down
To power down the unit, remove the power supply connection at the
rear of the unit.
Mode
ASI Rx
Active
Description
Unlit Unlit Input
disabled (ASI input)
Lit
Unlit
Input enabled, no ASI stream detected (not in
sync)
IP Tx
Lit
Lit
Input enabled, ASI stream detected (in sync)
Unlit Unlit Output
disabled (ASI output)
IP Rx
Unlit Lit
Output
enabled
Traffic and link indicator
Description
Green Lit
when
link
Blinks when data is transmitted or received.
Speed indicator
Description
Unlit 10Mbit/s
Green 100Mbit/s
Yellow 1000Mbit/s