INTERCONNECTION CABLE WIRING METHOD
The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the
EIA/TIA 568 B industry standard. Wiring is per the table and drawing below.
Pin
Wire Color
Pair
Function
1
White/Orange
2
T
2
Orange
2
R
3
White/Green
3
T
4
Blue 1
R
5
White/Blue
1
T
6
Green 3
R
7
White/Brown
4
T
8
Brown 4
R
Figure 5- View looking into RJ45 female
TECHNICAL SPECIFICATIONS
USB to host CPU
USB Type B female
USB to device
USB Type A female
USB output power
5V, 1.4A for 4 ports (<500mA per port)
Interconnect Cable
CAT5/5e Solid/Stranded UTP/STP; CAT6 Solid UTP/STP ; CAT6a Solid UTP;
CAT7 Solid STP EIA/TIA 568 B wiring
Remote Unit Power
100V to 240V at 50 or 60Hz-5VDC/3.0A via AC adapter
Local Unit Power
Powered by CPU
Operating temperature
32°F to 122°F (0°C to 50°C)
Storage temperature
-20°F to 140°F (-30°C to 60°C)
Operating and Storage Relative Humidity
0 to 90% non-condensing RH
Size (In.) WxDxH
5.1x3.1x1.2
Regulatory Approvals
RoHS, CE
Distances for CAT5/CAT5e, CAT6 and CAT7 Cables
CABLE
DISTANCE (feet)
CABLE
DISTANCE (feet)
CAT5/5e
Solid UTP/STP
200
CAT6
Solid UTP/STP
200
CAT5/5e
Stranded
UTP/STP
100
CAT6a
Solid UTP
195
(Distance Includes
10ft patch cable at
each end)
CAT7
Solid STP
200
Longer lengths of CATx cable are not recommended.