beautypg.com

Troubleshooting, Problem, Cause solution – North Star M157300E User Manual

Page 19: Any questions, comments, problems or parts orders

background image

Troubleshooting

19


Problem

Motor will not start

SOLUTION: A,B

Low/Surging pressure or no water flow

SOLUTION: C,D,E,F,G,H

No chemical injection SOLUTION:

I,J,K,L

Cause Solution

A- Tripped GFCI cord

Reset GFCI cord

B- Tripped motor relay

Reset motor

C- Insufficient water supply

See water supply section of this manual

D- Plugged pump inlet filter

See maintenance section of this manual

E- Wrong nozzle

Make sure high pressure nozzle is being used

F- Plugged nozzle

Remove nozzle, check for blockage

G- Worn nozzle

Replace nozzle

H- Leak in pressure hose

Replace pressure hose

I- Wrong nozzle

Make sure chemical nozzle is being used

J- Back pressure from extra long discharge hose

Try shorter hose

K- Leak in chemical siphon hose

Replace hose – use hose clamps if necessary

L- Chemical strainer not submerged

Make sure strainer is completely submerged




The manufacturer reserves the right to make improvements in design

and/or changes in specifications at any time without incurring any

obligation to install them on units previously sold.









Any Questions, Comments, Problems or Parts Orders

Call NorthStar Customer Service 1-800-270-0810