beautypg.com

N-Tron 405FXE-ST-YY User Manual

Page 7

background image

(Revised 2010-11-15)

7


405FX/405FXE HALF DUPLEX SETUP


While all RJ45 ports are Autosensing, the 405FX/405FXE Fiber Optic Port is factory configured for full
duplex operation. In the event half duplex operation is desired, follow these steps:

1. Remove the Voltage Input Power Plugs.
2. Remove the top cover (8 screws).
3. Remove the jumper plug (JP1) from pins 1 and 2.
4. Replace the top cover.
5. Proceed with the installation.

Full Duplex = Pins 1 and 2 shorted.
Half Duplex = Remove jumper.

In order to verify the jumper settings have been set correctly, for units which have the N-View option turned
on
, you should install N-ViewOPC Server software on a PC connected to the LAN. The software is freely
distributed on the ProductCD and our web site (

http://www.n-tron.com/html/opc.html

). Once N-ViewOPC is

installed, you should view the Ports Counter page to remotely monitor each connected port. You may find it
helpful to Copy [Alt]+[PrintScreen] the Port Counter information for each port and Paste [Control]+[V] into a
Windows document for further review. Please consult your N-View OPC Server Manual for additional
information.