LEAK TESTING

GENERAL

Although all gas connections on the grill are leak

tested at the factory prior to shipment, a complete

gas tightness check must be performed at the

installation site due to possible mishandling in

shipment, or excessive pressure unknowingly

being applied to the unit. Periodically check the

whole system for leaks following the procedures

listed below. If the smell of gas is detected at

anytime you should immediately check the entire

system for leaks.

BEFORE TESTING

Make sure that all packing material is removed

from the grill including the burner tie-down straps.

DO NOT SMOKE WHILE LEAK TESTING.

NEVER LEAK TEST WITH AN OPEN FLAME.

Make a soap solution of one part liquid detergent

and one part water. You will need a spray bottle,

brush, or rag to apply the solution to the fittings. For

the initial leak test, make sure the L.P. cylinder is

full.

TO TEST

Make sure all control valves are in the “OFF”

position. Turn the gas supply on. Check all

connections from the L.P. cylinder up to and

including the connection to the manifold pipe

assembly (the pipe that goes to the burners). Soap

bubbles will appear where a leak is present. If a

leak is present, immediately turn off the gas supply,

tighten any leaking fittings, turn gas on, and

recheck. Should the gas continue to leak from any

or all of the fittings, turn off the gas supply, and

contact our customer service at 1-800-913-8999.

Only those parts recommended by the

manufacturer should be used on the grill.

Substitution will void the warranty. Do not use the

grill until all connections have been checked and do

not leak.

Gas flow check:

Each grill burner is tested and adjusted at the

factory prior to shipment; however, variations in the

Adjustment Bolt

Locking Nut

Flames should be blue and stable with no yellow tips,

excessive noise or lifting. If any of these conditions

exist, check to see if the air shutter or burner ports are

blocked by dirt, debris, spider webs, etc. If you have

any questions regarding flame stability, please call

customer service at 1-800-913-8999.

ALWAYS CHECK FOR LEAKS AFTER EVERY LP

TANK CHANGE

local gas supply may make it necessary to adjust the

burners, the flames of the burners Should be visually

checked.

Check all gas supply fittings for leaks before each use.

It is handy to keep a spray bottle of soapy water near

the shut-off valve of the gas supply line. Spray all the

fittings. Bubbles indicate leaks.

Disconnected L.P. cylinders must have threaded valve

plugs tightly installed, and must not be stored in a

building, garage or any other enclosed area.

The gas must be turned off at the supply cylinder when

the unit is not in use.

If the appliance is stored indoors the cylinder must be

disconnected and removed from the appliance.

Cylinders must be

stored outdoors in a well-ventilated

area out of the reach of children.

12