Maintenance, Instructions for use, Scheduled maintenance table – Nilfisk-Advance America Terra 5200B User Manual
Page 12

INSTRUCTIONS FOR USE
10
Terra™ 5200B – 146 1996 000(2)2004-08
MAINTENANCE
The lifespan of the machine and maximum operating safety are ensured by correct and regular maintenance.
The following table summarizes the routine maintenance required. The intervals indicated can be changed to suit working
conditions. These must be defined by the person in charge of the maintenance.
All scheduled or extraordinary maintenance operations must be performed by skilled personnel, or by an Authorized
Service Center.
This manual describes only the easiest and most common maintenance procedures.
SCHEDULED MAINTENANCE TABLE
(*): for the related procedure, refer to the Service Manual.
(1): or before each start.
(2): and after the first 8 running-in hours
(3): replace hydraulic oil for the first time after 500 hours, then after 2,000 hours or every year
WARNING!
These operations must be carried out with the machine off, the ignition key not inserted and (if
required) the battery disconnected.
Moreover, carefully read the instructions in the Safety chapter.
NOTE
For other maintenance procedures contained in the Scheduled Maintenance Table, refer to the
specific Service Manual that can be consulted at any Service Center.
Maintenance operation
On delivery
Every 10
hours
Every 50
hours
Every 100
hours
Every 200
hours
Every 400
hours
Battery fluid level check
(1)
Hopper lifting system hydraulic oil level
check
(1)
Motor-to-main broom belt visual
inspection and tension check
(*)
Skirt height and operation check
Side and main broom height check
Frame dust filter cleaning and integrity
check
Pocket dust filter cleaning and integrity
check
Filter shaker operation check
(*)
Brake adjustment
(*)
Nut and screw tightening check
(*) (2)
Drive wheel chain tension check and
cleaning
(*)
Steering chain cleaning
(*)
Vacuum hose integrity check
(*)
Pulley-to-main broom belt replacement
(*)
Motor-to-main broom pulley V-belt
replacement
(*)
Hopper gasket integrity check
(*)
Hopper lifted position control microswitch
adjustment check
(*)
Hopper horizontal position control
microswitch adjustment check
(*)
Motor carbon brush check and
replacement
(*)
Hydraulic oil replacement
(*) (3)