Newcon Optik NIGHT VISION RIFLE SCOPE DN-140 User Manual

Page 6

background image

Warning!


After transportation or keeping the device at temperature
lower than -40

°C (-40°F), the device must be warmed up to

ambient temperature, from -10

°C (14°F) to +40°C (104°F),

relative humidity of 80% max. at 20

°C (68°F).


Precautions

DN-140 is a sophisticated precision optical instrument
equipped with electronics.
Therefore, it should be handled with due care.
• Keep your device away from direct sunlight, impacts,

dust, moisture, and sudden changes of temperatures.

• Do not touch the optical surfaces with fingers. Doing so

may damage the anti-reflection coating.

• Cleaning of optical surfaces is possible only with

professional camera lens cleaning supplies.

• To clean the exterior of the device, use a soft clean cloth.

• Do not take the cover off the lens if not necessary.

• Keep away from heating appliances and central heating.

• Make sure to switch off the unit during periods of non-

operation and when storing the device for long period of

time.

• Do not apply superfluous efforts at work with lens

assembly, agile elements and thread connections.

• Due to considerable optical magnification of the eye-

piece some small structures inside the tube coating in the
form of dark and/or white points may be seen in the field
of view which does not affect the serviceability of the
device.;

6

6.3 Operation at night

AT INSUFFICIENT AMBIENT

ILLUMINATION

At insufficient ambient illumination use the

Infra/Red illuminator (5). Activated by rotating switch (10)
clockwise.

If brightness of the screen is decreasing, replace the

batteries.

Take out the batteries during long periods of non-

operation.

7. a) USING THE DN-140 WITH A CAMERA OR A
VIDEO CAMCORDER
1. Pull out the rubber eye-guard (3) out from the eye-piece
(2).
2. Thread the camera adapter (optional) onto the filter
threads of your camera’s lens.
The camera adapter uses a 52mm thread size; a common
filter thread size for many Nikon, Canon and Minolta lenses.
You may purchase a step-up/step-down ring from your local
camera store if your lens does not use 52mm filters.
3. Fit the other end of the Camera adapter onto the eyepiece
socket of the scope. Lock the adapter in place by using the
three screws.
4. Connect the lens to the camera.
5. Make sure that you are in a dark area and that the lens
cap is attached, switch the unit ON.
6. Focus the camera lens until the image is sharp.

11