beautypg.com

Appendix b - troubleshooting, No display, No depth reading (--) at all depths – NorthStar Navigation EXPLORER D210 User Manual

Page 11: Erratic readings while moored, Erratic readings while moving, Erratic readings only while engine is running

background image

Northstar Explorer D210 Installation and Operation Manual

11

No display:

1. Check DC power connections and DC

polarity with voltmeter.

2. Check

fuse.

No depth reading (--) at all depths:

1. Check transducer for growth or multiple

coats of paint.

2. Check the transducer cable for cuts and

sharp bends.

3. Check that the transducer connection

behind the Explorer D210 is firm and free
of corrosion.

Erratic readings while moored:

1. Check transducer for growth or multiple

coats of paint.

Appendix B - Troubleshooting

Erratic readings while moving:

1. Cavitation (air) under the face of the

transducer. Review installation and
reinstall if necessary.

Erratic readings only while engine is running:

1. Re-route power and transducer cables

away from engine, ignition wires and
battery cables.

2. Add feed-through filter capacitor on the

positive terminal of the ignition coil.

3. Add an alternator whine filter to

alternator.

4. Replace spark plug wire with resistive

type.