Newcon Optik NVS7-2/4x User Manual
Page 6
IMAGE INTENSIFIER TUBE SPECIFICATIONS
The unit is utilizing a small size image intensifier with direct image transfer.
The tube contains a microchannel plate, multi-alkaline metal cathode, yellow-green color
screen, built in electronics high voltage DC to DC converter and flat surface glass
input-output windows.
Main parameters:
Image Intensifier Type (Generation)
2+
3
Photocathode operating diameter, mm
18
Photocathode type
S-25 A
3
B
5
(GaAs)
Resolution, lines/mm
30-64 45-64
Photocathode sensitivity, min:
Integral, µA/ lm
400-650 1300-2200
Spectral at λ = 850 nm, mA/W
15 90
Light amplification
20-26000
25-30000
Image magnification
1
Dark background brightness, max, cd/m
2
1⋅10
−3
3⋅10
−3
Signal-to-noise ratio, min
16-20 16-24
Current consumption, max, mA
20 25
Voltage, V
2.8 ± 0.8
Weight, g
55
Dimensions
Length, mm
22.5
Diameter, mm
43.0
Tube life until reduced parameters, hrs
10,000
10,000
Keep time, years
12
15
Ambient temperature range, °C
± 40
± 50
Spatial frequency-contrast characteristic
Frequency, lines/mm
Contrast transfer
Coefficient (Gen. 2+)
Contrast transfer
Coefficient (Gen. 3)
2.5 0.83
0.86
7.5 0.56
0.58
15.0 0.26
0.28
Field of view cleanness
Zone
Zone
Maximum diameter of defects
Admitted total
#
Diameter,
Neglected
Admitted
area of defects,
Gen. 2+
Mm
∅, mm
Q-ty mm
2
1
0 – 9.0
0.10
0.15
2
0.15
2
9.0 - 14.4
0.12
0.25
3
0.30
3 14.4
-18.0 0.15 0.35 3 0.50
Gen. 3
1
0 – 8.75
0.06
0.15
1
0.072
2
8.75 – 14.0
0.08
0.25
2
0.27
3
14.0 – 18
0.10
0.35
3
0.45
4. CONSTRUCTION
1. On-Off, I/R Switch
2. Mounting Socket
3. Eye-piece adjustments
4. Eyepieces
5. Battery House Cover
6.
Objective Lens focus
5
2
6
1
3
4
Figure 1