beautypg.com

Controls and connectors, Rear panel – Nady Systems TMP-1 MICPREAMP User Manual

Page 6

background image

6

(10)

(11)

(12)

REAR PANEL

Rear Panel

(10) AC POWER CORD IEC CONNECTOR WITH INTEGRATED

FUSE HOLDER

This standard IEC power cord receptacle is used to connect the

AC power to your unit. It features a built-in fuse holder for a

5X20mm, 0.5A/250V slow-blow fuse. If the fuse continuously

blows, shut off the unit and have it serviced by qualified service

personnel.

(11) AC VOLTAGE SELECT SWITCH

Before plugging in the power cord, check to see that the unit is set

for the proper voltage for your area: ~115V (60Hz) or ~230V

(50Hz).

(Note: Use at the improper voltage can damage your unit and void

the warranty.)

(13)

(12) OUTPUTS

Unbalanced 1/4" (6.3mm) and balanced XLR outputs

(Note: Only one output (1/4" or XLR) can be used at one time. Do

not connect to both at the same time, or the signal will be

severely distorted.)

(13) INPUTS

Unbalanced 1/4"(6.3mm) and balanced XLR inputs.

(Note: Only one input per each channel (1/4" or XLR) can be

used at one time. Do not connect to both at the same time or the

signal will be severely distorted.)

CONTROLS AND CONNECTORS