Operation / maintenance – Napoleon Fireplaces GI3016-P User Manual
Page 10
10
W415-0171 / E / 01.10.05
If your masonry fireplace is equipped with a fresh air inlet
in the floor of the firebrick chamber, the insert is able to
take outside air directly into the unit through an opening in
its base thereby eliminating the need to use preheated
room air for combustion. The flow of air may be adjusted
through the use of a damper located below the louvre ac-
cess door. The damper should be kept closed (pushed all
the way in) when the unit is not in operation or if no outside
air is available. The damper is fully open when pulled for-
ward (one inch from the closed position).
FIGURE 22
Never obstruct the flow of combustion or
ventilation air.
When lit for the first time, the stove will emit a slight odour
for a few hours. This is a normal temporary condition
caused by the curing of the logs and the "burn-in" of inter-
nal paints and lubricants used in the manufacturing proc-
ess and will not occur again.
Simply open a window to sufficiently ventilate the room.
After extended periods of non-operation such as following
a vacation or a warm weather season, the fireplace may
emit a slight odour for a few hours. This is caused by dust
particles in the heat exchanger burning off. Open a window
to sufficiently ventilate the room.
Call a qualified service technician. Force or attempted
repair may result in a fire or explosion.
D Do not use this insert if any part has been under water.
Immediately call a qualified service technician to inspect
the unit and replace any part of the control system and
any gas control touched by water.
A This stove has a pilot which must be lit by hand while
following these instructions exactly.
B Before lighting, smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or turn
by hand, do not try to repair it.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone
in your building.
8. Depress and hold the gas knob while lighting the pilot
with the push button igniter. Keep the knob fully de-
pressed for one (1) minute, then release. If the pilot does
not continue to burn, repeat steps 3 through 7.
9. With the pilot lit, turn the gas knob counter-clock-
wise
to "on" position.
10. If your insert is equipped with a flame adjustment
valve, push and turn the knob to "high".
11. If your insert is equipped with a remote "on-off" switch,
the main burner may not come on when you turn the gas
valve to "on" or "high". The remote switch must be in the
"on" position as well to ignite the main burner.
12. Turn on all electrical power to the insert.
1. Stop! Read all the safety information above. When
lighting and relighting, the gas knob cannot be turned
from "pilot" to "off" unless the knob is depressed.
2. Turn off all electrical power to the stove.
3. Turn the gas knob
clockwise to off.
4. Wait 5 minutes for any gas in the combustion cham-
ber to escape. Continue to the next step if you do NOT
smell any gas. If you smell gas, STOP! and follow the
instructions in "What to do if You Smell Gas" listed above.
5. If the unit is equipped with a flame adjustment valve,
turn clockwise to off.
6. Locate the pilot situated in front of the rear log.
7. Turn the gas knob counter-clockwise to
"pi-
lot" position.
2. Push in gas control knob slightly and turn clock-
wise to off.
Do not force.
1. Turn off all electrical power to the unit if service is
to be performed.
THERMOPIL
ELECTRODE
PILOT BURNER
GAS VALVE
OPERATION / MAINTENANCE
OPERATING INSTRUCTIONS
FRESH AIR DAMPER SYSTEM
FOR YOUR SAFETY READ BEFORE LIGHTING:
WHAT TO DO IF YOU SMELL GAS:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS