MODEL QTXEN110SFLT

1b. Mount housing anywhere between

trusses, joists, or I-joists using hanger

bars.

Sliding hanger bars are provided to allow for accurate posi-

tioning of housing anywhere between framing. They can be

used on all types of framing (I-joist, standard joist, and truss

construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the

SCREWS supplied. Make sure TABS face “up” as shown.

Use the set of channel mounting holes (marked “STD”) to

mount the housing flush with the bottom of the drywall. Use

the other set of holes (not marked) to mount the housing

flush with the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

Extend HANGER BARS to the width of the framing.
Hold ventilator in place with the hanger bar tabs wrapping

around the BOTTOM EDGE OF THE FRAMING.

NAIL ventilator to framing or fasten with screws (not provided)

through HOLES near nails.

*

To ensure a noise-free mount: Secure hanger bars together

with SCREWS or use a pliers to crimp mounting channels

tightly around hanger bars.

*

SCREW (2)

HOLE FOR OPTIONAL

SCREW MOUNTING (4)

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE

OF FRAMING

4. Connect electrical wiring.

Run 120 VAC house wiring to installation location. Use

proper UL approved connector to secure house wiring to

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

MODEL 66V/66W, P66V/P66W

3-FUNCTION CONTROL (PURCHASE SEPARATELY)

LIGHT

(ON/OFF)

COM

NIGHT LIGHT

(ON/OFF)

FAN

(AUTO/OFF)

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

BLU

RED

WHT

UNIT

ORG

BLK

WHT

GRD

BLK

RED

LIGHT

NIGHT LIGHT

WHT

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

2. Attach damper/

duct connector.

Snap damper / duct con-

nector onto housing. Make

sure connector is flush

with top of housing and

damper flap falls closed.

3. Install

6-inch round duc-

twork.

Connect 6-inch round

ductwork to damper / duct

connector. Run ductwork

to a roof cap or wall cap.

Tape all ductwork con-

nections to make them

secure and air tight.

MODEL 77DV, 77DW, P77DV, P77DW

4-FUNCTION CONTROL (PURCHASE SEPARATELY)

FAN

(ON/OFF/AUTO)

120

VAC

LINE

IN

SWITCH BOX

GRD

RED

RED

BLU

UNIT

RED

BLU

WHT

GRD

WHT

BLK

BLK

RED

WHT

BLK

NIGHT LIGHT

(ON/OFF)

LIGHT

(ON/OFF)

COM

COM

BLK

BLK

WHT

ORG

WHT

BLK

WHT

BRN

HUMIDITY

CONTROL

FAN

WHT

NIGHT LIGHT

LIGHT

WIRING OPTION #1 - Allows fan to operate in automatic mode or manual mode

(for odor control) by cycling ON/OFF switch.

WIRING OPTION #2 - Fan can be turned ON, OFF, or set to operate automatically.

TAB