beautypg.com

Technical data – Neumann.Berlin TLM 50 User Manual

Page 4

background image

Errors excepted, subject to changes • Printed in Germany • Publ. 01/08 058155/A04

Technical Data

Acoustical operating principle ............................................... Pressure transducer
Directional pattern ................................................................................. Omnidirectional
Frequency range .................................................................................... 20 Hz...20 kHz
Sensitivity at 1 kHz into 1 kohm ............................................................. 20 mV/Pa
Rated impedance ................................................................................................... 50 ohms
Rated load impedance ................................................................................ 1000 ohms
Signal-to-noise ratio, CCIR

1)

(rel. 94 dB SPL) ............................................ 68 dB

Signal-to-noise ratio, A-weighted

1)

(rel. 94 dB SPL) ............................. 81 dB

Equivalent noise level, CCIR

1)

............................................................................... 26 dB

Equivalent noise level, A-weighted

1)

........................................................... 13 dB-A

Maximum SPL for THD 0.5%

2)

...................................................................... 136 dB

Maximum SPL for THD 0.5% with preattanuation

2)

....................... 146 dB

Maximum output voltage ..................................................................................... 10 dBu
Dynamic range of the microphone amplifier (A-weighted) .......... 123 dB
Supply voltage (P48, IEC 61938) ........................................................ 48 V ± 4 V
Current consumption (P48, IEC 61938) ........................................................ 3 mA
Matching connector ................................................................................................... XLR3F
Weight ................................................................................................................................. 490 g
Diameter .......................................................................................................................... 56 mm
Length ............................................................................................................................ 145 mm

®

Neumann is a registered trademark of the Georg Neumann GmbH in certain countries.

measured in free-field conditions (IEC 60268-4), tolerance ± 2 dB

1)

according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS

2)

measured as equivalent el. input signal