Presonus 13 – PreSonus EQ3B User Manual
Page 15
PRESONUS
13
PUMP - Make the COMP16 ‘pump up the prime’. A setting for
making the compressor pump in a desirable way. This effect is
good for snare drum to increase the length of the transient by
bringing the signal up after the initial spike. Very contemporary.
Threshold
Ratio
Attack
Release
0dB 1.9:1
1mS
0.001mS
3 Tamer – Tame that funky low end. Designed to help control low
end transients. This setting is especially useful for Bass Guitar.
Threshold
Ratio
Attack
Release
-8dB 2:1
1mS
50mS