NOTE: Operating time will vary depending upon the type, capacity charge
level of the battery, and the power draw of the AC products you are using.
With a normal vehicle battery and a 100 watt load (such as a small television)
you can expect an operating time of 2 to 3 hours. It is recommended that you
start your vehicle once an hour when using the RPPD100D for extended
periods of time to prevent draining the battery.

WARNING

: To prevent personal injury or loss of life, never start or leave your

engine running in a poorly ventilated area such as a garage.

Helpful Formulas:

To Convert AMPS to WATTS: AMPS X VOLTS = WATTS
To Convert WATTS to AMPS: WATTS ÷ VOLTS = AMPS
These formulas yield a close approximation of the continuous loads of a product.

E

Es

sttiim

ma

atte

ed

d W

Wa

atttts

s U

Us

se

ed

d b

by

y C

Co

om

mm

mo

on

n A

Ap

pp

plliia

an

nc

ce

es

s a

an

nd

d T

To

oo

olls

s

Appliance

Approx. Watts

Cell phone

10

VCR

40-60

CD or DVD player

40

Xbox Console

100

7" to 10" LCD television

50 » 150

Laptop computer (recharge battery)

150

Specifications

:

Operating AC Voltage (Normal) . . . . . . . . . . . . . . . . . . . . . . 105~125-Volts AC
DC Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10~15-Volts DC
Continuous AC Power Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Watts
USB Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Volts DC
Maximum AC Power Output (Surge) . . . . . . . . . . . . . . . . . . . . . . . . . 175 Watts
AC Output Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Hz ±2Hz
AC Output Waveform . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modified Sine Wave
Battery Drain with No AC Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.50 Amps
Efficiency (Maximum). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87%
Ambient Operating Temperature Range. . . . . . . . 14°F (-10°C) ~ 104°F (40°C)
Low Battery Shut Down Point . . . . . . . . . . . . . . . . . . . . . . 10.5 ±0.3-Volts DC
High Voltage Shut Down Point . . . . . . . . . . . . . . . . . . . . . . 15.5 ±0.5-Volts DC
Specifications Subject to Change without Notice