Specifications – Powerware 3115 User Manual
Page 3

Specifications
I
N P U T
Power Levels
300, 420, and 650 VA; see Model Selection Guide
Topology
Standby
Operating Voltage
120 Vac models: 103 to 142 (default);
Range
88 to 142 Vac (user-selectable)
230 Vac models: 196 to 260 (default);
166 to 260 Vac (user-selectable)
Frequency
50/60 Hz
Frequency Range
57 to 63 Hz @ 60 Hz
47 to 53 Hz @ 50 Hz
Current
3.5A @ 120 Vac; 1.8A @ 230 Vac
Connections
See Model Selection Guide
Protection
Resettable circuit breaker
Total Harmonic
Same as input
Distortion (THD)
TVSS Rating
Total energy rating more than 240J, 6500A
Surge voltage let-through (percentage of applied ANSI
C62.41 Cat. A +6kV test waveform)
≤
5%
AC O
U T P U T
, N
O R M A L
M
O D E
Voltage
120 and 230 Vac; see Model Selection Guide
Frequency
50/60 Hz auto-selectable; same as input
Frequency
Same as load
Regulation
Overload
110% + 10% overload for 3 minutes. SMPS load, pure sine
wave input. 120% + 10% for 10 cycles
Efficiency
96% straight through mode @ full load and fully charged
battery
AC O
U T P U T
, B
AT T E R Y
M
O D E
Voltage Regulation
Nominal voltage ±5%; -10% at low battery
Waveform
Step wave (synthesized sine)
Frequency
50/60 Hz ±1 Hz of auto-selected nominal frequency
Regulation
Transfer Time
4 milliseconds, typical
Efficiency
>70%, 100% SMPS load
B
AT T E RY
Backup Time
See Battery Run Times table
Battery Recharge
12 hours to 95% usable capacity @ nominal line after full
Time
load discharge
Start-On-Battery
Startup with UPS batteries in absence of utility power
Battery
12 and 6 Vdc batteries; Valve-Regulated Lead Acid (VRLA),
minimum 3 year float service life at 25°C
Battery Protection
Internal batteries protected by either a fuse or circuit
breaker. Fuse ratings: 30A/32 Vdc and 40A/32 Vdc
Charger Voltage
13.5 to 13.8 Vdc
Maximum Charge
12V battery = 0.7 ± 0.1A
Current
6V battery = 1.2 ± 0.1A
Replacement/
User-replaceable
Service
R
E G U L AT O R Y
S
TA N D A R D S A N D
R
E Q U I R E M E N T S
Safety
120 Vac models: UL1778, CAN/CSA C22.2 No. 107.1
230 Vac models: EN50091-1, C-Tick
EMI/EMC
120 Vac models: FCC Part 15 Class B
230 Vac models: EN50091-2
Immunity
IEC 61000- 4-2, -3, - 4
Audible Noise
< 40 dBA
Operating Altitude
3000m (10,000 ft max.)
Operating
0°C to 40°C, 0 to 1500 meters above sea level
Temperature
0°C to 35°C, 1500 to 3000 meters above sea level
Transit and
-15°C to +55°C
Storage Temperature
Relative Humidity
0 to 95% noncondensing
M
E C H A N I C A L
Dimensions
See Model Selection Guide
and Weight
In a perfect world, your electrical
equipment would always receive clean
power. However, without UPS protection,
power quality can be erratic, causing serious
damage to your files and hardware.
Series 3 Power Protection
The Powerware 3115 is a Series 3 UPS,
meaning it protects your equipment from
three basic power problems: power failures,
power surges, and power sags.
These three power problems can cause
hardware damage, keyboard lockups,
data corruption, and data loss.
Acting as a defensive barrier between your
equipment and dirty power, the Powerware
3115 eliminates the threats caused by
power failures, power surges, and power
sags, thus increasing productivity and your
bottom line.
Power Failures
A complete loss of utility power that can be
caused by events such as lightning strikes,
grid over-demands, accidents, and natural
disasters.
Power Surges
With voltages above 110% of nominal,
surges can be triggered by rapid reduction
in power loads, heavy equipment being
turned off, or by utility switching.
Power Sags
The opposite of surges, sags are caused by a
startup of large loads, utility switching,
utility equipment failure, lightning, and
power service that is too small for the
demand.