Immunity Characteristics
• EN55024:1998+A1:2001
• IEC 61000-4-2:2001 Electrostatic Discharge Immunity Test
• IEC 61000-4-3:2002 Radiated Radio-Frequency Electromagnetic Field Immunity Test
• IEC 61000-4-4:1995+A1:2000+A2: 2001 Electrical Fast Transient/Burst Immunity Test
• IEC 61000-4-5:2001 Surge Immunity Test
• IEC 61000-4-6:2001 Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
• IEC 61000-4-8:2001 Power Frequency Magnetic Field Immunity Test
• IEC 61000-4-11:2001 Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests
Safety
• UL/CSA 60950-1
Environmental Specifications
Temperature
• Operating:
-10 to 55 °C
• Operating
Survival:
-25 to 65 °C
• Storage:
-30 to 75 °C
Humidity
• Operating:
5 to 90% RH, 40 °C, non-condensing
• Non-operating:
5 to 93% RH, non-condensing
Altitude
• Operating:
10,000 ft (IEC 60068 PT2-13, 4 hours)
• Non-operating:
15,000 ft (IEC 60068 PT2-13, 4 hours)
Vibration
• Operating (random): 10 to 500 Hz, 3.0 G rms acceleration, 3 hours per axis
Shock