beautypg.com

Troubleshooting guide technical data, Recycling time, sec – Profoto ACUTE2 1200 User Manual

Page 26

background image

26

Troubleshooting Guide

Technical data

Recycling time, sec

Mains voltage

Acute2 1200

Acute2 2400

240V 50 Hz

0.09-1.6 s

0.18-3.2 s

100V 50 Hz

0.12-2.7 s

0.24-5.1 s

117V 60 Hz

0.09-1.5 s

0.17-2.9 s

Duration and recycling data are approximate and may differ slightly between units due
to component variations

Size (height x length x width)
2400Ws

13x19x30cm (5.1x7.5x11.8in) incl. Handle

1200Ws

13x19x22cm (5.1x7.5x8.7in) incl. Handle

Weight
2400Ws

5.9kg (12.9 lb)

1200Ws

4.1kg (9.0 lb)

Max Modelling lamp
500W and 1000W per generator

Problem

• No ready lamp but ready sound

• No flash

• Fuses keep blowing

• Continuous red light in Photocell

• Generator works badly or shuts

off after a few seconds

• Slow recharging /recycling

• Flashing red light in Photocell

• Bad mains quality?

Action

• Change ready lamp

• Check flash tube

• Reduce recycling speed

• Generator is overheated

• Check voltage settings on

generator.

• Low mains voltage? - Reduce the

BRACKET(15)

• Indicates slow recycling setting

• Check setting of recycling time