Installation (Electrical)

ELECTRICAL, ALL HSI UNITS

Electrical Rating

50/60 Hz

120 V.A.C. ONLY

NOTE

The transformer is pre-wired at the factory for 120 VAC operation ,connect line
supply to the line terminal block inside junction box. Use caution in con-
necting supply to proper Line (L), Neutral (N), and Ground (GND) terminals;
see below, Figure 5.

NOTE

If any of the original wiring supplied with this heater must be replaced, installer must supply

(No. 18 AWG 105° C. U.L. approved AWM low energy stranded) copper wire or it’s equivalent.

In Canada: wires must be CSA approved.

WARNING

The heater must be electrically grounded and bonded in accordance with local codes or, in the absence
of local codes, with the latest national electrical codes ANSI/NFPA No. 70.

In Canada: CSA standard C22.1 Canada Electrical Code Part 1 and/or local codes.

Always use crimp type connectors when connecting two wires.

L

N

GREEN WIRE

WHITE WIRE

BLACK WIRE

GROUND
CONNECTION

NEUTRAL / WHITE 120 VAC

POSITIVE LINE FOR 120 VOLTS AC

INTERNAL
FACTORY WIRES

LINE TERMINAL BLOCK

Figure 5.