Page 2
*
16 HP Tecumseh OHV engine
*
Cast-iron cylinder sleeve
*
Low oil sensor
*
Receptacles on control panel
*
Electric start
*
7 gallon plastic fuel tank
*
Portability Kit
A.
120 V, 20 Ampere Duplex Receptacle
This duplex is split so that 20 amps of current may be
drawn from each half of the receptacle. However, total power
drawn must be kept within nameplate ratings. These
receptacles may be used along with the twistlock receptacle
provided the generator is not overloaded.
B.
120/240 V, 30 Ampere Twistlock Receptacle
A maximum of 30 amps may be drawn from the 120/240
volt receptacle, provided it is the only receptacle used.
However, current must be limited to the nameplate rating. If the
120/240 volt receptacle is used along with the 120 volt
receptacle, the total load drawn must not exceed the nameplate
ratings.
C.
Circuit Breakers
The receptacles are protected by an AC circuit breaker. If
the generator is overloaded or an external short circuit occurs,
the circuit breaker will trip. If this occurs, disconnect all
electrical loads and try to determine the cause of the problem
before attempting to use the generator again. If overloading
causes the circuit breaker to trip, reduce the load. NOTE:
Continuous tripping of the circuit breaker may cause
damage to generator or equipment. The circuit breaker may
be reset by pushing the button of the breaker.
An “Off-On-Start” rotary key switch (D) is provided on the
control panel. All necessary wiring is provided. The battery is
not included - must be purchased separately.
Battery Installation
Coleman Powermate recommends a 12 v battery with at
least 235 cranking amps. Model U1L, Lawn and Garden
Battery. Place the battery in the position provided. Then place
the bolts through the loops on the Hold-Down bracket. Place
the assembly over the battery and place the bolts through the
holes on the battery pan and tighten down the Hold-Down
assembly with the 1/4-20 nuts provided. Spacers may be
added depending on the battery height.
WARNING: Batteries contain sulfuric acid
(when filled). May contain explosive gasses.
Always abide by safety warnings provided
with the battery.
-
Keep sparks, flame and cigarettes away.
-
Hydrogen gas is generated during
charging and discharging.
-
Always shield eyes, protect skin and
clothing when working near batteries.
Connect the red 8 ga. battery lead to the positive battery
post and the black 8 ga. battery lead to the negative battery
post with the bolts and nuts provided (Items F, G, and H).
The engine contains an internal battery charger which is
connected to the positive (Red) battery lead. Battery charging
will occur when the engine is running.
CAUTION: Do Not allow the positive (Red)
battery terminal to come in contact with any
metal parts of the unit. Engine or battery
damage may result.