The handset function menu default settings are shown in the table
below; these may be changed as described above in Function Menu
Programming. Some of these functions (Mute, Redial, Forward, etc.)
are activated by softkeys or
FCN
menu options on the SpectraLink
6000 and SpectraLink 8020/8030 Wireless Telephones.
FCN + 0
FNC
FCN + 1
MUTE
FCN + 2
TRF
FCN + 3
CNF
FCN + 4
LNR/SPD
FCN + 5
RECALL
FCN + *
EXIT MENUS
Program NEC NEAX
The System Administrator programs the NEAX for use with the
SpectraLink 6000 System or SpectraLink handsets using the NEC
Maintenance and Administration Terminal.
Copy settings from a wired set
If possible, copy the settings from a wired telephone with similar
settings and restrictions to a handset. Once this is done, you can
program the options on one handset, then copy the programming to
other handsets or groups of handsets. If your NEC systems are
networked, you may prefer to build each set individually rather than
use the Copy feature.
Program features for handset
Program the following features for the handsets:
•
Prime Line:
Selects the line that users get when they go off hook. To
give users inside dial tone when they go off-hook, assign Intercom
as Prime Line.
•
Ringing Line Preference:
Controls the way a station answers a
ringing line. To assign outside lines to display at all handsets, but
not ring at all handsets, Disable Direct Ring.
•
Toll Restrictions:
Control which lines are allowed to make or receive
outside calls. They are programmed through a series of toll tables,
which are then assigned to lines and stations. If you copied an
existing wired set, Toll Restrictions will be set correctly for the
handset.