13 — ENG

MAINTENANCE

GENERAL RECOMMENDATIONS

The warranty of the generator does not cover items that
have been subjected to operator abuse or negligence.
To receive full value from the warranty, operator must
maintain the generator as instructed in this manual.

ENGINE MAINTENANCE

Refer to the Engine Operator's manual for service and
maintenance of the engine.

Note 1: Service more frequently when used in dusty areas.
Note 2: Change engine oil every 25 hours when used under heavy load or in high ambient temperatures.
Note 3: These items should be serviced by your servicing dealer.

GENERATOR MAINTENANCE

Your generator should be kept clean and dry at all
times. The generator should not be stored or operated
in environments that includes excessive moisture, dust
or any corrosive vapors. If these substances are on the
generator, clean with a cloth or soft bristle brush. Do
not use a garden hose or anything with water pressure
to clean the generator. Water may enter the cooling air
slots and could possibly damage the rotor, stator and
the internal windings of the generator head.

Emission-related items.

Customer Responsibilities Table

ITEM

Perform at every indicated month or operating
hour interval, whichever comes first.

Before

use

First

Month

or

5 Hrs.

Every

Season

or

25 Hrs.

Every

Season

or

50 Hrs.

Every

100 Hrs.

Every

150 Hrs.

Engine oil

Check

Change

(2)

Air cleaner

Check

Clean

(1)

Replace

(200 Hrs.)

Spark plug

Check-Clean

Replace

(200 Hrs.)

Spark arrester

Clean

Fuel tank and strainer

Clean

(3)

Idle speed

Check-Adjust

(3)

Valve clearance

Check-Adjust

(3)

Fuel line

Check

Every 2 years (Replace if necessary) (3)

Regular Service Period