6.3 ERROR MODE

- Error Messages

If a CD is not operative or stopped during operation due to an error, the error mode is turned on and cause(s) of
the error is indicated with a corresponding number. This arrangement is intended at reducing nonsense calls from
the users and also for facilitating trouble analysis and repair work in servicing.

(1) Basic Indication Method

1) When SERRORM is selected for the CSMOD (CD mode area for the system), error codes are written to DMIN
(minutes display area) and DSEC (seconds display area). The same data is written to DMIN and DSEC. DTNO
remains in blank as before.

2) Head unit display examples

Depending on display capability of LCD used, display will vary as shown below. xx contains the error number.

8-digit display

6-digit display

4-digit display

ERROR–xx

ERR–xx

E–xx

(2) Error Code List

Code

Class

Displayed error code Description of the code and potential cause(s)

10

Electricity

Carriage Home NG

CRG can't be moved to inner diameter.

SERVO LSI Com-

CRG can't be moved from inner diameter.

munication Error

Failure on home switch or CRG move mechanism.

Communication error between microcomputer and SERVO LSI.

11

Electricity

Focus Servo NG

Focusing not available.

Stains on rear side of disc or excessive vibrations on REWRITABLE.

12

Electricity

Spindle Lock NG

Spindle not locked. Sub-code is strange (not readable).

Subcode NG

Failure on spindle, stains or damages on disc, or excessive vibrations.

A disc not containing CD-R data is found.

Turned over disc are found, though rarely.

CD signal error.

17

Electricity

Setup NG

AGC protection doesn't work. Focus can be easily lost.

Damages or stains on disc, or excessive vibrations on REWRITABLE.

30

Electricity

Search Time Out

Failed to reach target address.

CRG tracking error or damages on disc.

44

Electricity

ALL Skip

Skip setting for all track.

(CD-R/RW)

50

Mechanism

CD On Mech Error

Mechanical error during CD ON.

Defective loading motor, mechanical lock and mechanical sensor.

A0

System

Power Supply NG

Power (VD) is ground faulted.

Failure on SW transistor or power supply (failure on connector).

Remarks: Mechanical errors are not displayed (because a CD is turned off in these errors).

Unreadable TOC does not constitute an error. An intended operation continues in this case.

Upper digits of an error code are subdivided as shown below: