Specifications – Pelco EH8100 User Manual
Page 9

C1407M-H (1/07)
9
Specifications
Electrical
Input Voltage
120 VAC (230 VAC optional) for heaters
Power Requirements
40 watts (EH8104)
80 watts (EH8106)
Connector
16-pin receptacle with jam nut
Mating Connector
MS-type connector (supplied)
Maximum Cable Distances
120 VAC
EH8104
EH8106
16 AWG (1.5 mm
2
)
4,477 ft (1365 m)
2,238 ft (682 m)
18 AWG (1.0 mm
2
)
2,821 ft (860 m)
1,410 ft (430 m)
20 AWG (0.5 mm
2
)
1,773 ft (540 m)
(1,252) 1,040 (316)
230 VAC
16 AWG (1.5 mm
2
)
16,449 ft (5,014 m)
8,224 ft (2,507 m)
18 AWG (1.0 mm
2
)
10,364 ft (3,159 m)
5,182 ft (1,579 m)
20 AWG (0.5 mm
2
)
6,514 ft (1,985 m)
3,257 ft (993 m)
Heater
EH8104
Two, 20 watts each, 120 VAC
EH8106
Two, 40 watts each, 120 VAC
Heaters are thermostatically controlled to come on at 40°F (4°C) and go off at 60°F (16°C)
General
Construction
Aluminum 6061 T6
Finish
Outside
Gray polyester powder coat
Inside Black
anodized
Dimensions
See Figure 3
Front Window
EH8104
4-inch diameter tempered glass, 0.225-inch thick
EH8106
6-inch diameter tempered glass, 0.225-inch thick
Camera Mounting
Multiple mounting holes on camera sled allow for linear adjustment
Maximum Camera/Lens Size
EH8104
3-inch diameter x 14-inch length (8 x 35 cm) or
14 (L) x 2.5 (W) x 2.5 (H) inches (35 x 6 x 6 cm)
EH8106
5-inch diameter x 18-inch length (13 x 46 cm) or
18 (L) x 4.0 (W) x 4.0 (H) inches (46 x 10 x 10 cm)
Enclosure
Mounting
Adjustable cradle secured with type 316 stainless steel bands
Purge Fitting
Standard Schraeder valve to allow enclosure to be filled with dry nitrogen
Purge Fitting
Prevents over-pressurization of enclosure
Weight
EH8104
8 lb (4 kg)
EH8106
15 lb (7 kg)