PYLE Audio MN300HGA User Manual
Owner ’ s operation and installation manual
1
B LU E FL A ME V E NT -F RE E
NATURAL GA S G A R AG E
H EATE R
OWNER’S OPERATION AND INSTALLATION MANUAL
MN300HGA MN300TGA
NON-THERMOSTAT AND
THERMOSTAT MODEL
WARNI NG: I m proper inst al l ati on,
adjustment, alteration, service or maintenance
can cause injury or property damage. Refer to
this manual for correct installation and
operational procedures. For assistance or
additional information consult a qualified
installer, service agency, or gas supplier.
This appliance may be installed in an aftermar-
ket* permanently located, m anufactured
(mobile) home, where not prohibited by local
codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This
appliance is not convertible for use with other
gases.
Do not store, or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
l
Do not try to light any appliance.
l
Do not touch any electrical switch; do not
use any phone in your building.
l
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
l
If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed by a
qu alified in staller, servic e a genc y or ga s
supplier.
Important Safety Information..................................... 2
Fresh Air for Combustion and Ventilation ............... 4
Installation..................................................................... 8
Operating Your Heater............................................... 11
Cleaning&Maintenance.............................................13
Trouble Shooting.........................................................14
Specifications..............................................................17
Illustrate Parts Breakdown MN300TGA .................18
Parts List MN300TGA .................................................19
Illustrate Parts Breakdown MN300HGA .................20
Parts List MN300HGA .................................................21
Table of Contents
*Aftermarket: Completion of sale, not for purpose of
resale, from the manufacturer.
WATER VAPOR: A BY-PRODUCT OF UNVENTED ROOM
HEATERS
W ater vaporis a by-product of gas combustion.An
unvented room heater produces approximately one (1)
ounce (30ml) of water for every 1,000 BTU’s (.3KW’s)
of gas input per hour. Refer to page 3.
Installer: Please leave these instructions with
the consumer.
Consumer: Please retain these instructions for
future use.
PRO-COM PHONE NUMBER: (877)886-5989
WARNING:
If the information in this
manual is not followed exactly, a fire o r
e x p lo s io n m a y re s u lt causing property
damage, personal injury, or loss of life.
WARNING:
This is an unvented gas-fired
heater. It uses air (oxygen) f r o m t h e r o o m
i n w h ic h i t i s installed. Provisions for
adequate combustion and ventilation air must
b e p ro v id e d . R e f e r to A ir F o r Combustion
and Ventilation section on page 4 of this
manual.
CONTINENTAL APPLIANCE INC/U.S. OFFICE
5 Musick
4600 Highlands Parkway S.E
.
Irvine
Suite # D/E
CA 92618
Smyrna, GA 30080
Nanjing PRO-COM Electric Appliance Co.,Ltd.
#6 Chuangye Road,High New Tech.Zone,
Great Bridge Road North,Nanjing,210061,
China.
PR-ML062-09-0504