Hamilton Sundstrand Company Fuel Metering Valves XVG User Manual
Page 14
Register
Number
XVG/eXVG Parameter
Name
Write
Access
Description Type
Default
Value
3541 IDM_PARITY
W2
Modbus parity: 0 = None, 1 = Odd, 2 = Even
U16
0
3542 IDM_RXMSGTMOUT
W2
Modbus receive message timeout: 0 = auto-
scale to 3.5 character times for current baud
rate. Other values: n * 0.1ms timeout.
Range: 0 to 1000.
U16 0
3543 IDM_MODELNO[0]
W4
X
3544 IDM_MODELNO[1]
W4
V
3545 IDM_MODELNO[2]
W4
G
3546 IDM_MODELNO[3]
W4
3547 IDM_MODELNO[4]
W4
3548 IDM_MODELNO[5]
W4
3549 IDM_MODELNO[6]
W4
3550 IDM_MODELNO[7]
W4
3551 IDM_MODELNO[8]
W4
3552 IDM_MODELNO[9]
W4
3553 IDM_MODELNO[10]
W4
3554 IDM_MODELNO[11]
W4
3555 IDM_MODELNO[12]
W4
3556 IDM_MODELNO[13]
W4
3557 IDM_MODELNO[14]
W4
3558 IDM_MODELNO[15]
W4
Model Number: null terminated string, 16
bytes max.
Each register contains one ASCII
representation of one character string.
Model number has maximum 16 characters.
ASCII
3559 IDM_PARTNO[0]
W4
1
3560 IDM_PARTNO[1]
W4
2
3561 IDM_PARTNO[2]
W4
3
3562 IDM_PARTNO[3]
W4
4
3563 IDM_PARTNO[4]
W4
5
3564 IDM_PARTNO[5]
W4
3565 IDM_PARTNO[6]
W4
3566 IDM_PARTNO[7]
W4
3567 IDM_PARTNO[8]
W4
3568 IDM_PARTNO[9]
W4
3569 IDM_PARTNO[10]
W4
3570 IDM_PARTNO[11]
W4
3571 IDM_PARTNO[12]
W4
3572 IDM_PARTNO[13]
W4
3573 IDM_PARTNO[14]
W4
3574 IDM_PARTNO[15]
W4
Part Number: null terminated string, 16 bytes
max.
Each register contains one ASCII
representation of one character string. Part
number has maximum 16 characters.
ASCII
5500 5501
IDM_BAUD_RATE
W2
Baud Rate: 9600, 19200, 38400 or 57600
U32
19200
5502 5503
IDM_ANINPUTHYS
W4
4-20mA Input Hysteresis: ADC Count range
0 – 273
U32
0
5504 5505
IDM_DATE
W4
Date: range 0-0xFFFFFF, format MMDDYY
in BCD
U32
666
5506 5507
IDM_SERIALNO
W4
Serial Number: range 1-0x7FFFFFFF
U32
24680
14