beautypg.com

Limiting values, Handling, Thermal characteristics – Philips TDA8783 User Manual

Page 7

background image

2002 Oct 23

7

Philips Semiconductors

Product specification

40 Msps, 10-bit analog-to-digital
interface for CCD cameras

TDA8783

LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134).

Note

1. The supply voltages V

CCA

, V

CCD

and V

CCO

may have any value between

0.3 and +7.0 V provided that the supply

voltage difference

V

CC

remains as indicated.

HANDLING

Inputs and outputs are protected against electrostatic discharges in normal handling. However, to be totally safe, it is
desirable to take normal precautions appropriate to handling integrated circuits.

THERMAL CHARACTERISTICS

SYMBOL

PARAMETER

CONDITIONS

MIN.

MAX.

UNIT

V

CCA

analog supply voltage

note 1

0.3

+7.0

V

V

CCD

digital supply voltage

note 1

0.3

+7.0

V

V

CCO

output stages supply voltage

note 1

0.3

+7.0

V

V

CC

supply voltage difference

between V

CCA

and V

CCD

1.0

+1.0

V

between V

CCA

and V

CCO

1.0

+4.0

V

between V

CCD

and V

CCO

1.0

+4.0

V

V

i

input voltage

referenced to AGND

0.3

+7.0

V

V

CLK(p-p)

AC input voltage for switching
(peak-to-peak value)

referenced to DGND

V

CCD

V

I

o

output current

10

mA

T

stg

storage temperature

55

+150

°

C

T

amb

ambient temperature

20

+75

°

C

T

j

junction temperature

150

°

C

SYMBOL

PARAMETER

CONDITIONS

VALUE

UNIT

R

th(j-a)

thermal resistance from junction to ambient in free air

76

K/W