Double acting only
180˚ Models (ACX AND ADX)
Performance Characteristics
ADX Torques
ACX Torques
Air Torque
Spring
Series
Spring
40 psig (2.8 bar)
60 psig (4.1 bar)
80 psig (5.5 bar)
Torque
Set
in-lb
Nm
in-lb
Nm
in-lb
Nm
in-lb
Nm
61
2
-
-
25
2.8
57
6.4
39
4.4
61S
2
-
-
16
1.8
21
2.4
21
2.4
8
19
2.1
90
10.2
161
18.2
62
7.0
64
10
-
-
60
6.8
131
14.8
78
8.8
12
-
-
30
3.4
101
11.4
93
10.5
14
-
-
-
-
71
8.0
109
12.3
8
76
8.6
255
28.8
433
48.9
150
16.9
68
10
-
-
186
21.0
365
41.2
187
21.1
12
-
-
117
13.2
296
33.4
225
25.4
14
-
-
48
5.4
227
25.6
262
29.6
Weight
Operating
Air Consumption
Air Consumption
Bore
Stroke
AD
AC
Time
in
3
cc
Series
Inch
mm
Inch
mm
lb
kg
lb
kg
sec
Port “A”
Port “B”+
Port “A”
Port “B”+
61
1.8
45.7
1.0
25.4
1.9
0.9
2.4
1.1
0.8
4.5
5.7
73.8
93.4
61S
1.8
45.7
1.0
25.4
1.4
0.7
1.7
0.8
0.8
6.1
3.1
100.0
50.0
64
3.2
81.3
0.7
17.8
5.5
2.5
6.4
2.9
1.5
16.0
23.0
262.3
377.0
68
4.3
109.2
1.0
25.4
11.6
5.3
13.6
6.2
2.8
37.0
49.0
606.6
803.3
40 psig (2.8 bar)
60 psig (4.1 bar)
80 psig (5.5 bar)
Series
in-lb
Nm
in-lb
Nm
in-lb
Nm
61
59
6.7
89
10.1
119
13.4
61S
-
-
45
5.1
59
6.7
64
139
15.7
210
23.7
281
31.7
68
351
39.7
530
59.9
709
80.1
9
Pneumatic Actuators
Parker Hannifin Corporation
Instrumentation Valve Division
Jacksonville, Alabama