beautypg.com

Setup and hold timing – Planar High Brightness User Manual

Page 10

background image

EL320.256-FD7 Operations Manual (020-0353-00A)

8

Table 4. Timing Characteristics.

Description Min

Max

Unit

Note

T1 Vertical Front Porch

60

µs

1

T2 VS HIGH/LOW time

1

tVCLK

2

T3 Vertical Blank

40

µs

T4 Vertical Period

256

tHS

VS frequency

120

Hz

Description Min

Typ

Unit

Note

T5 HS setup to VS

1

µs

3

T6 HS hold from VS

3

µs

T7 HS Low Time

4

tVCLK

T8 HS High Time

320

320

tVCLK

4

T9 HS period (tHS)

19

µs

Notes:

1. This time is needed to display the last row and to initiate the following
frame.

2. Only rising edge is used.

3. 2 tVCLK minimum

4. The number of VCLK pulses during HS high time must be even.
Video clock VCLK must be kept running continuously.

Setup and Hold Timing

Figure 4. Setup and Hold Timing.

Table 5. Setup and Hold Timing.

Symbol Description

Min

Max

tSU

HS, VID, TVID setup to VCLK

8ns

tHOLD

HS, VID, TVID hold from VCLK

8ns

tWL

VCLK low width

16ns

tWH

VCLK high width

16ns

tVCLK VCLK

period

40ns

VCLK frequency

25 MHz