Inrush current, Electrical data – Philips Compact HID Lamp and Gear User Manual
Page 78
OEM Catalogue 2009/2010
2.78
HID-PrimaVision Compact for CDM lamps - Independent
HID-PV C 35/70 /I
HID-PV C 150 /I
Inrush current
Type
Maximum
gear number
on MCB
(x)
Inrush
current
Peak
(A)
Inrush
current
Width
(ms)
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz SOFT START
58
9
2.5
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz
24
24
0.35
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz SOFT START
32
9
2.5
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz
14
33
0.5
HID-PrimaVision Compact 150 /I CDM 220-240V 50/60Hz
6
50
0.50
HID-PrimaVision Compact 2x35/1 CDM 220-240V 50/60Hz
tbf
tbf
tbf
Electrical data
Type
Number
of
Lamps
(x)
Rated
Gear-
Lamp
Power
Power
losses
gear
(W)
Line
Frequency
(Hz)
Line
Voltage
(V)
T-case
life
(ºC)
T-case
maximum
(ºC)
T-ambient
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz SOFT START
1
35
4.5
50/60
220-240
80
80
50
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz
1
35
4.5
50/60
220-240
70
80
55
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz SOFT START
1
70
6.8
50/60
220-240
75
75
45
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz
1
70
6.5
50/60
220-240
70
80
45
HID-PrimaVision Compact 150 /I CDM 220-240V 50/60Hz
1
150
10.0
50/60
220-240
70
80
45
HID-PrimaVision Compact 2x35 /I CDM 220-240V 50/60Hz
2
35
13.0
50/60
220-240
70
80
55
Electrical data
Type
Ignition
Voltage
(kV)
Cable-Cap
outputwires
mutual
(pF)
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz SOFT START
5.0
150
HID-PrimaVision Compact 35 /I CDM 220-240V 50/60Hz
4.5
120
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz SOFT START
5.0
150
HID-PrimaVision Compact 70 /I CDM 220-240V 50/60Hz
4.5
120
HID-PrimaVision Compact 150 /I CDM 220-240V 50/60Hz
5.0
200
HID-PrimaVision Compact 2x35 /I CDM 220-240V 50/60Hz
4.5
120