42

3. Management with Web browser software

3.6 Command Control via the Network (continued)

Command Format
Command formats differ among the different communication ports.

● TCP #23

You can use the RS-232C commands without any changes. The reply data

format is the same as the RS-232C commands. However, the following reply

will be sent back in the event of authentication failure when authentication is

enabled.

Header

Data length

RS-232C command

Check Sum Connection

ID

0x02

0x0D

13 bytes

1 byte

1 byte

Reply

Error code

0x1F

0x04

0x00

Header

→ 0x02, Fixed

Data length

→ RS-232C commands byte length (0x0D, Fixed)

RS-232C commands → RS-232C commands that start with 0xBE 0xEF

(13 bytes)

Check Sum

→ This is the value to make zero on the addition of the

lower 8 bits from the header to the checksum.

Connection ID

→ Random value from 0 to 255 (This value is attached

to the reply data)

● TCP #9715

Send Data format

The following formatting is added to the header (0x02), Data length (0x0D),

Checksum (1byte) and Connection ID (1 byte) of the RS-232C commands.