Panasonic PC8 User Manual
Page 4
Panasonic Protocol Converter Manual V10.2 5Mar 09
Page 4/16
Technical Specification
Power Requirements
9Vdc 500mA
Input
2 or 4 wire RS485 (switch selectable, SW3/8)
Panasonic
RS485
9600,N,8,1
or
19200,N,8,1
Outputs
8 * RS485, either 2 or 4 wire
Maximum cable run approx 4000 Feet/1200m
Facilities
LED as power and data indication
Other Outputs
RS232 monitor output via chassis mounted DB9 connector.
Boxed Dimensions
19” 1U rack 100mm deep rack mountable case.
Version History
V10.2 5 Mar 2009
Update to show new 00007-6 PCB format.
V10.1 6 Sept 2007
Addition of notes concerning Vicon dome integration and SX650 matrix firmware.
V10 17 August 2007
Added support for Vicon dome protocol at 4800 or 9600 baud
V9 11 May 2007
Added Wash/Wipe support for Pelco protocol
V8 14 July 2006
Added support for Dennard dome protocol at 9600 baud
V7 8 Sept 2005
Added support for Pelco P at 2400, 4800 or 9600 baud
V2 5 March 2004
Improved control, LED status improved, added support for patrol and path
V1 26 Mar 2003
VCL TP protocol (9600,N,8,1)