Warnings, Cautions and Operating Instructions
WARNING: These lamps must be operated in fixtures
designed for use with High Pressure Sodium lamps.The
fixture wattage rating must match the wattage indicated
on the outer glass bulb. Do not scratch the outer bulb or
subject it to pressure as this could cause the outer bulb to
crack or shatter. A partial vacuum in the outer bulb may
cause glass to fly if the glass is struck. Operating the lamp
improperly may result in PERSONAL INJURY,
PROPERTY DAMAGE, BURNS AND FIRE.
1. If the outer glass bulb is broken, shut off power
immediately and remove the lamp after it has cooled.
2. Use only auxiliary equipment meeting Philips and/or
ANSI standards. Use within voltage limits recommended
by ballast manufacturer.
A. Operate lamp only within specified limits of operation.
B. For total supply load refer to ballast manufacturers
electrical data.
3. Protect lamp base, socket and wiring against moisture,
corrosive atmospheres and excessive heat.
4. Replace the lamp if the outer glass bulb has been
scratched, cracked or damaged in any way.
5. If a lamp bulb support is used, be sure to insulate the
support electrically so as to avoid possible decomposi-
tion of the bulb glass.
6. Do not use this lamp in a fixture which redirects a
substantial portion of the energy toward the arc tube
and its immediate vicinity, as this may lead to very early
lamp failure.
7. Take care in handling and disposing of lamps. If arc tube
is broken, avoid skin contact with any of the contents
or fragments.
8. The arc tube of this lamp contains sodium and mercury.
Dispose of in accordance with federal, state and
local requirements.
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Basic High Pressure Sodium Lamps
1) Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least
50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For HPS lamps with a rated average life of 18,000 hours, life is based on survival of 67% of the lamps.
2) Measured at 100 hours of life in vertical operating position.
3) Approximate mean lumen output at 40% of lamp rated average life. Measured in vertical operating position.
4) Approximate color temperature in Kelvin degrees.
Above specifications subject to change without notice.
Philips Basic High Pressure Sodium (HPS) Lamps
Ordering, Electrical and Technical Data
© 2008 Philips Lighting Company. All rights reserved.
Printed in USA 4/08
P-5921
www. philips.com
Philips Lighting Company
200 Franklin Square Drive
P.O. Box 6800
Somerset, NJ 08875-6800
1-800-555-0050
A Division of Philips Electronics North America Corporation
Philips Lighting
281 Hillmount Road
Markham, Ontario
Canada L6C 2S3
1-800-555-0050
A Division of Philips Electronics Ltd.
Rated
Approx.
Approx.
Color
Product
Pkg
Bulb
ANSI
MOL
LCL
Avg. Life
Initial
Mean
Temp.
Number
Description
Watts
Qty
Bulb
Finish
Base
Code
(In.)
(In.)
(Hrs.)
1
Lumens
2
Lumens
3
(K)
4
15243-9
C70S62/BASIC HPS
70
12
T-14
Clear
Mogul
S62
7
3
⁄
4
5
18,000
6000
4500
2100
15244-7
C100S54/BASIC HPS
100
12
T-14
Clear
Mogul
S54
7
3
⁄
4
5
18,000
9000
6750
2100
15245-4
C150S55/BASIC HPS
150
12
T-14
Clear
Mogul
S55
7
3
⁄
4
5
18,000
15,000
11,250
2100
15246-2
C250S50/BASIC HPS
250
12
T-14
Clear
Mogul
S50
9
3
⁄
4
5
3
⁄
4
18,000
25,500
19,125
2100
15247-0
C400S51/BASIC HPS
400
12
T-14
Clear
Mogul
S51
9
3
⁄
4
5
3
⁄
4
18,000
47,500
35,625
2100