10

recommended. Mix gasoline and oil at a ratio

of 40:1. A 40:1 ratio is obtained by mixing 3.2

ounces (95 ml) of oil with 1 gallon (4 liters) of

unleaded gasoline. DO NOT USE automotive

oil or marine oil. These oils will cause engine

damage. When mixing fuel, follow instructions

printed on container. Once oil is added to

gasoline, shake container momentarily to

assure that the fuel is thoroughly mixed. Always

read and follow the safety rules relating to fuel

before fueling your unit.

BAR AND CHAIN LUBRICATION

The bar and chain require lubrication. The chain

oiler provides continuous lubrication to the chain

and guide bar. Be sure to fill the bar oil tank

when you fill the fuel tank (Capacity = 4.6 fl. oz.).

Lack of oil will quickly ruin the bar and chain.

Too little oil will cause overheating shown by

smoke coming from the chain and/or discolor-

ation of the bar. The oil output is automatically

metered during operation. Always fill the bar oil

tank when you fill the fuel tank.

Genuine Poulan or Poulan PRO bar and

chain oil is recommended to protect your unit

against excessive wear from heat and fric-

tion. Poulan or Poulan PRO oil resists high

temperature thinning. If Poulan or Poulan

PRO bar and chain oil is not available, use a

good grade SAE 30 oil.
S

Never use waste oil for bar and chain

lubrication.

S

Always stop the engine before removing

the oil cap.

IMPORTANT

Experience indicates that alcohol blended

fuels (called gasohol or using ethanol or

methanol) can attract moisture which leads to

separation and formation of acids during stor-

age. Acidic gas can damage the fuel system

of an engine while in storage. To avoid engine

problems, empty the fuel system before stor-

age for 30 days or longer. Drain the gas tank,

start the engine and let it run until the fuel lines

and carburetor are empty. Use fresh fuel next

season. Never use engine or carburetor

cleaner products in the fuel tank or permanent

damage may occur. See the STORAGE sec-

tion for additional information.

HOW TO STOP YOUR UNIT

S

To stop the engine, move the ON/OFF

switch to the OFF position.

ON/OFF Switch

HOW TO START YOUR UNIT

WARNING:

Make sure the chain will

not make contact with any object while start-

ing the engine. Never try to start the unit when

the guide bar is in a cut. Avoid any contact

with the muffler. A hot muffler can cause seri-

ous burns.

Starting Position

HELPFUL TIP

If your engine still does not

start after following these

instructions, please call

1--800--554--6723.

STARTING A COLD ENGINE

NOTE:

DO NOT squeeze the throttle trigger

until the engine has started and runs.

1. Set unit on a flat surface.

2. Move ON/OFF switch to the ON position.

3. Slowly press the primer bulb 6 times.

4. Move the start lever to the START posi-

tion.

Start

Lever

Starter Handle

Primer Bulb

Muffler

5. Pull starter rope handle sharply until en-

gine starts and runs.

6. Allow unit to run for 5 seconds, then fully

squeeze the throttle trigger to disengage

the starting system.

STARTING A WARM ENGINE

1. Move ON/OFF switch to the ON position.

2. Squeeze and hold the throttle trigger.

Keep throttle trigger fully squeezed until

engine runs smoothly.

3. Pull starter rope sharply while squeezing

throttle trigger until engine runs.

NOTE:

Normally, the warm starting proce-

dure can be used within 5--10 minutes after

the unit is turned OFF. If the unit sits for more

than 10 minutes without being ran, it will be

necessary to start the unit by following the

steps under STARTING A COLD ENGINE or

following the starting instruction steps shown

on the unit.

STARTING A FLOODED ENGINE

Flooded engines can be started by placing

the ON/OFF switch in the ON position. Move

the start lever to the RUN position and fully

squeeze throttle trigger. Pull the starter han-

dle repeatedly while squeezing throttle trigger

until engine starts and runs. This could re-

quire pulling the starter handle many times,

depending on how badly the unit is flooded.

If the unit still doesn’t start, refer to

TROUBLESHOOTING

TABLE

or

call