beautypg.com

Perlick Z2148EMU User Manual

Page 2

background image

INSTALLATION INSTRUCTIONS

TAPPING AND CLEANING PROCEDURES

Fig. 2

ON

Fig. 3

CLEAN

Fig. 1

OFF

45

°

1. Disconnect keg coupler from keg.

2. Open faucet to relieve line pressure and

close when flow ceases.

3. Disconnect beer line including seal washer

from keg coupler.

4. Connect beer line including seal washer to

external thread of Universal Empty Keg
Sensor and turn Beer Flow Control Handle
to OFF position.

(See Fig. 1). In this

position the Universal Empty Keg Sensor
acts as a shut-off valve.

5. Where fitted, remove retaining clip/spring

and check ball from keg coupler center
probe.

6. Insert seal washer supplied into coupling

nut on Universal Empty Keg Sensor and
couple to the keg coupler.

7. Connect keg coupler to keg and tap keg.

8. Turn Beer Flow Control Handle to CLEAN.

(See Fig. 3).

9. Open beer faucet. When solid beer

appears, close the faucet.

10. Turn Beer Flow Control Handle ON.

(See Fig. 2). The line is full and ready
for service.

EXISTING
BEER LINE
AND SEAL
WASHER

P/N 43739
UNIVERSAL
EMPTY KEG
SENSOR AND
SEALING
WASHER

REMOVE
CLIP/SPRING
AND CHECK
BALL FROM
COUPLER

Warranty

Perlick Products are fully guaranteed against defects in both material and
workmanship for a period of one year from date of sale. Defective parts will be
replaced on a no-charge basis, F.O.B. our factory, subject to our inspection. We
are not responsible for parts damaged by alteration, unauthorized service,
accident or abuse. All costs incident to replacement to include freight, labor and/or
loss of sales are incidental to this warranty and must be borne by the user.

No. 43657

No. 43681

Single Adapter

Dual Adapter

Cleaning Adapters

Beer Flow Control

Handle Operating

Positions

Filling the Lines the First Time

1. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

2. Tap fresh keg.

3. Turn Beer Flow Control Handle to CLEAN.

(See Fig. 3).

4. Open the beer faucet. When solid beer

appears, close the faucet. The line is full.

5. Turn Beer Flow Control Handle ON.

(See

Fig.2). The line is full and ready for service.

When Tapping Fresh Kegs

1. Remove coupler from empty keg.

2. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

2. Tap fresh keg in normal manner.

3. Turn Beer Flow Control Handle to CLEAN.

position.

(See Fig. 3). Wait for five seconds

then turn to ON position.

(See Fig. 2).

To Restart System

If beer does not flow, first turn the Flow Control
Handle to OFF.

(See Fig. 1). Then turn Handle to

the CLEAN position.

(See Fig. 3). Wait for five

seconds then turn the Handle to ON position.
(See Fig. 2).

To Clean

1. Untap Keg in usual manner.

2. Turn Beer Flow Control Handle OFF.

(See Fig. 1).

3. Attach cleaning adapter. Use Perlick’s

single cleaning adapter, No. 43657, if
cleaning from faucet to keg. If two or
more lines are cleaned, use Perlick’s
dual cleaning adapter, No. 43681.

4. Turn Beer Flow Control Handle to

CLEAN and clean as usual.

(See Fig. 3).

5. After flushing, turn Beer Flow Control

Handle OFF and retap keg.

(See Fig. 1).

6. To restore service, see above instructions.